AC/DC Current Probe
TCP0150
|
Features & Benefits
- Easy-to-Use and Accurate AC/DC
Current Measurements
- Connects Directly to DPO4000, MSO4000,
and DPO7000 Series Oscilloscopes Using the TekVPI Probe Interface
- DC to 20 MHz Bandwidth
- 150 ARMS Maximum
Current Capability
- 500 A Peak Pulse Current Capability
- High Accuracy with Typically Less Than 1% DC Gain Error
- Accurately Measures Current levels as Low as 5 mA
- Low
Noise and DC Drift
- Provides Automatic Units Scaling and Readout
on the Oscilloscope's Display
- Remote Programmable GPIB Control
for ATE systems
- Split-core Probe Head Construction Allows
Easy Connection to Conductors
- Easy to Degauss and Autozero
- Setup Controls and Probe Status and Diagnostic Indicators are
Provided on Both the Probe Hardware and through an Easy-to-Access
Scope UI Display Menu
Applications
- Power Supplies
- Semiconductor
Devices
- Power Inverters/Converters
- Electronic Ballasts
- Industrial/Consumer Electronics
- Motor Drives
- Transportation Systems
-
Note: Requires DPO7000 Series
Firmware Version 3.0.2 or greater. Requires MSO/DPO4000 Firmware Version
2.06 or greater.
TCP0150
is a high performance and easy-to-use 150 A AC/DC current probe designed
for use and direct connection (without the need of an additional power
supply) to the TekVPI™ probe interface used on Tektronix DPO4000,
MSO4000, and DPO7000 Series oscilloscopes. This AC/DC current measurement
probe provides 20 MHz of frequency bandwidth with selectable range
control for 25 A and 150 A measurement ranges. It also provides low-current
measurement capability and accuracy to current levels as low as 5 mA
per division – important for achieving broad dynamic current range
of high-level and low-level measurement signals.
Characteristics
Warranted
|
Characteristic
|
Description
|
|
Bandwidth
|
DC to ≥20 MHz (-3 dB). Derate with Frequency. See Figure 1.
(Calculated from Rise Time BW = .35/Rise Time)
|
|
Rise Time
|
≤17.5 ns
|
|
Max RMS Current
|
150 A
|
|
Max Peak Pulse Current
|
500 A
|
|
Minimum Sensitivity
|
5 mA (on oscilloscope’s 1 mV/div setting)
AC Coupling
(on oscilloscopes that support AC/DC coupling)
|
|
Current Ranges
|
25 A and 150 A
|
|
Max Bare-wire Voltage
|
600 VRMS CAT I and II
300 VRMS CAT III
|
Typical
|
Characteristic
|
Description
|
|
DC Accuracy
|
±1% Typical
3% Warranted
|
|
Max Amp-second Product
|
|
25 A Range
|
3,000 Aµs
|
|
150 A Range
|
15,000 Aµs
|
|
Insertion Impedance
|
0.03 Ω at 1 MHz
|
|
0.075 Ω at 5 MHz
|
|
.125 at 10 MHz
|
|
.3 at 20 MHz
|
|
Signal Delay
|
21 ns
|
|
Displayed RMS Noise
|
≤500 μARMS (probe only)
|
Environmental
|
Characteristic
|
Description
|
|
Temperature
|
|
Operating
|
0 ºC to +50 ºC
|
|
Nonoperating
|
-40 ºC to +75 ºC
|
|
Humidity
|
|
Operating
|
5% to 95% RH (Relative Humidity) at up to +30 ºC
5%
to 85% RH above 30 ºC up to +50 ºC, noncondensing
|
|
Nonoperating
|
5% to 95% RH (Relative Humidity) at up to +30 ºC
5%
to 85% RH above 30 ºC up to +75 ºC, noncondensing
|
|
Altitude
|
|
Operating
|
Up to 2,000 meters (6,560 feet)
|
|
Nonoperating
|
Up to 12,000 meters (40,000 feet)
|
Physical Characteristics
|
Dimension
|
Meters
|
Inches
|
|
Cable Length
|
2 meters
|
79 in.
|
|
Probe head size
|
|
Length
|
26.8 cm
|
10.55 in.
|
|
Width
|
4.1 cm
|
1.6 in.
|
|
Height
|
15.6 cm
|
6.13 in.
|
|
Max Conductor Diameter
|
21 mm x 25 mm
|
0.83 in. x 1.0 in.
|
|
Weight
|
kg
|
lb.
|
|
Shipping
|
.7865
|
1.734
|
|
Power Requirements
|
TCP0150 is powered directly by the DPO4000, MSO4000
and DPO7000 Series oscilloscopes using TekVPI interface
|
Recommended Oscilloscopes
DPO4000,
MSO4000, and DPO7000 Series oscilloscopes with TekVPI probe interface.
Note: Requires DPO7000 Series Firmware Version 3.0.2
or greater. Requires MSO/DPO4000 Firmware Version 2.06 or greater.
Figure 1.
Figure 2.
Figure 3: Do not apply currents greater than
the max continuous current for more than 10 seconds to minimize heating
effects.
Ordering Information
TCP0150
AC/DC
Current Probe with TekVPI Interface.
Includes: Protective
Cover (016-1924-xx), and Certificate of Traceable Calibration and
Data Standard.
Options
|
Option
|
Order
|
|
Opt. L0
|
Standard English Language Instruction Manual (071-xxxx-xx)
|
|
Opt. L5
|
Substitutes Japanese Language Instruction Manual
|
|
Opt. L7
|
Substitutes Simplified Chinese Language Instruction Manual
|
Recommended Accessories
|
Order
|
Accessory
|
|
015-0601-50
|
Current Loop, 1 Turn, 50 Ω with BNC connector used for Performance
Verification
|
|
067-1701-xx
|
TekVPI Calibration Fixture
|
|
067-1686-xx
|
Cal/Deskew Fixture for DPO7000/70000 Series
|
Service Options
|
Option
|
Description
|
|
Opt. CA1
|
Provides coverage for a single Calibration Event
|
|
Opt. C3
|
Calibration Service 3 years
|
|
Opt. C5
|
Calibration Service 5 years
|
|
Opt. D3
|
Calibration Data Report 3 Years (with Opt. C3)
|
|
Opt. D5
|
Calibration Data Report 5 Years (with Opt. C5)
|
|
Opt. R3
|
Repair Service 3 Years
|
|
Opt. R5
|
Repair Service 5 Years
|
|
|
Product(s) are manufactured in ISO registered facilities.
|
|
Product(s) complies with IEEE Standard 488.1-1987, RS-232-C,
and with Tektronix Standard Codes and Formats.
|
51W-20815-0, 14-AUG-2007
|
|
 |