AC/DC Current Probe

TCP0150

Features & Benefits

  • Easy-to-Use and Accurate AC/DC Current Measurements
  • Connects Directly to DPO4000, MSO4000, and DPO7000 Series Oscilloscopes Using the TekVPI Probe Interface
  • DC to 20 MHz Bandwidth
  • 150 ARMS Maximum Current Capability
  • 500 A Peak Pulse Current Capability
  • High Accuracy with Typically Less Than 1% DC Gain Error
  • Accurately Measures Current levels as Low as 5 mA
  • Low Noise and DC Drift
  • Provides Automatic Units Scaling and Readout on the Oscilloscope's Display
  • Remote Programmable GPIB Control for ATE systems
  • Split-core Probe Head Construction Allows Easy Connection to Conductors
  • Easy to Degauss and Autozero
  • Setup Controls and Probe Status and Diagnostic Indicators are Provided on Both the Probe Hardware and through an Easy-to-Access Scope UI Display Menu

Applications

  • Power Supplies
  • Semiconductor Devices
  • Power Inverters/Converters
  • Electronic Ballasts
  • Industrial/Consumer Electronics
  • Motor Drives
  • Transportation Systems
  • Note: Requires DPO7000 Series Firmware Version 3.0.2 or greater. Requires MSO/DPO4000 Firmware Version 2.06 or greater.

TCP0150 is a high performance and easy-to-use 150 A AC/DC current probe designed for use and direct connection (without the need of an additional power supply) to the TekVPI™ probe interface used on Tektronix DPO4000, MSO4000, and DPO7000 Series oscilloscopes. This AC/DC current measurement probe provides 20 MHz of frequency bandwidth with selectable range control for 25 A and 150 A measurement ranges. It also provides low-current measurement capability and accuracy to current levels as low as 5 mA per division – important for achieving broad dynamic current range of high-level and low-level measurement signals.

Characteristics

Warranted

Characteristic

Description

Bandwidth

DC to ≥20 MHz (-3 dB). Derate with Frequency. See Figure 1. (Calculated from Rise Time BW = .35/Rise Time)

Rise Time

≤17.5 ns

Max RMS Current

150 A

Max Peak Pulse Current

500 A

Minimum Sensitivity

5 mA (on oscilloscope’s 1 mV/div setting)

AC Coupling (on oscilloscopes that support AC/DC coupling)

Current Ranges

25 A and 150 A

Max Bare-wire Voltage

600 VRMS CAT I and II

300 VRMS CAT III

Typical

Characteristic

Description

DC Accuracy

±1% Typical

3% Warranted

Max Amp-second Product

   25 A Range

3,000 Aµs

   150 A Range

15,000 Aµs

Insertion Impedance

0.03 Ω at 1 MHz

0.075 Ω at 5 MHz

.125 at 10 MHz

.3 at 20 MHz

Signal Delay

 21 ns

Displayed RMS Noise

≤500 μARMS (probe only)

Environmental

Characteristic

Description

Temperature

   Operating

0 ºC to +50 ºC

   Nonoperating

-40 ºC to +75 ºC

Humidity

   Operating

5% to 95% RH (Relative Humidity) at up to +30 ºC

5% to 85% RH above 30 ºC up to +50 ºC, noncondensing

   Nonoperating

5% to 95% RH (Relative Humidity) at up to +30 ºC

5% to 85% RH above 30 ºC up to +75 ºC, noncondensing

Altitude

   Operating

Up to 2,000 meters (6,560 feet)

   Nonoperating

Up to 12,000 meters (40,000 feet)

Physical Characteristics

Dimension

Meters

Inches

Cable Length

2 meters

79 in.

Probe head size

   Length

26.8 cm 

10.55 in.

   Width

4.1 cm

1.6 in.

   Height

15.6 cm

6.13 in.

Max Conductor Diameter

21 mm x 25 mm

0.83 in. x 1.0 in.

Weight

kg

lb.

Shipping

.7865

1.734

Power Requirements

TCP0150 is powered directly by the DPO4000, MSO4000 and DPO7000 Series oscilloscopes using TekVPI interface

Recommended Oscilloscopes

DPO4000, MSO4000, and DPO7000 Series oscilloscopes with TekVPI probe interface.

Note: Requires DPO7000 Series Firmware Version 3.0.2 or greater. Requires MSO/DPO4000 Firmware Version 2.06 or greater.


Figure 1.


Figure 2.


Figure 3: Do not apply currents greater than the max continuous current for more than 10 seconds to minimize heating effects.

Ordering Information

TCP0150

AC/DC Current Probe with TekVPI Interface.

Includes: Protective Cover (016-1924-xx), and Certificate of Traceable Calibration and Data Standard. 

Options

Option

Order

Opt. L0

Standard English Language Instruction Manual (071-xxxx-xx)

Opt. L5

Substitutes Japanese Language Instruction Manual

Opt. L7

Substitutes Simplified Chinese Language Instruction Manual

Recommended Accessories

Order

Accessory

015-0601-50

Current Loop, 1 Turn, 50 Ω with BNC connector used for Performance Verification

067-1701-xx

TekVPI Calibration Fixture

067-1686-xx

Cal/Deskew Fixture for DPO7000/70000 Series

Service Options

Option

Description

Opt. CA1

Provides coverage for a single Calibration Event

Opt. C3

Calibration Service 3 years

Opt. C5

Calibration Service 5 years

Opt. D3

Calibration Data Report 3 Years (with Opt. C3)

Opt. D5

Calibration Data Report 5 Years (with Opt. C5)

Opt. R3

Repair Service 3 Years

Opt. R5

Repair Service 5 Years




CE Mark
ISO9001 Product(s) are manufactured in ISO registered facilities.

GPIB Logo Product(s) complies with IEEE Standard 488.1-1987, RS-232-C, and with Tektronix Standard Codes and Formats.

51W-20815-0, 14-AUG-2007

(WebID: 13428)

back to top
Product Information
Introduction
Characteristics/Specs
Ordering Information
Printable Data Sheet (378 KB)

Purchasing Information
Check List Price
Request Sales Contact
Request a Demo

Request a Quote

Additional Information
Where To Buywidth=10
Buy Onlinewidth=10
On-line Probe Selectorwidth=10

Navigate Data Sheets

Data Sheets > Products > Accessories > Oscilloscope Accessories > Oscilloscope Probes > Current Probes

Data Sheets > Products > Oscilloscopes > Oscilloscopes 500MHz to 5GHz > DPO4000 Series

Data Sheets > Products > Oscilloscopes > Oscilloscopes up to 500MHz > DPO4000 Series

Data Sheets > Products > Oscilloscopes > Oscilloscopes 500MHz to 5GHz > DPO7000 Series

Data Sheets > Products > Oscilloscopes > Oscilloscopes up to 500MHz > DPO7000 Series

Data Sheets > Products > Oscilloscopes > Oscilloscopes 500MHz to 5GHz > MSO4000 Series

Data Sheets > Products > Oscilloscopes > Oscilloscopes up to 500MHz > MSO4000 Series



Tektronix documents require the latest version of PDF Adobe Acrobat Reader.