Features & Benefits
- HiPower Finder and B-H Analysis
Pinpoint the Source of Reliability Problems
- Power Loss Measurements
at the Switching Device and Magnetic Component Improve Switching Power
Supply Efficiency
- Sophisticated Report Generation Saves Time
- Customizable Safe Operating Area Mask Testing with Linear and
Log Scale for Reliability Testing
- In-circuit Bpeak, Permeability,
and Coercive Force Measurements Determine the Reliability of the Magnetic
Component
- Automatic Ripple Measurement Setup Eliminates Manual
Processes
- Spectrum Analysis Locates Ripple and Noise on the
Output Voltage and EMI Issues with the Switching Power Supply
- Precompliance Testing to the EN61000-3-2, EN61000-3-2 AM14,
and MIL Standard 1399 (400 Hz) Reduces Compliance Test Time and Risk
- Automated THD, True Power, Apparent Power, Power Factor, and
Crest Factor Features Eliminate Tedious Manual Calculations
- Modulation Analysis Quickly Provides Accurate Active Power Factor
Characterization
- Automatic Deskew Ensures Accurate, Time-correlated
Results
- Correct Scale Factor and Unit Display while Using
Third-party Current Probes Eliminates Manual Calculations and Human
Error
Applications
- Power-loss Measurement at
Switching Device and Magnetic Component
- Characterization
of Power Semiconductor Devices
- Optimal Drive Characterization
of Synchronous Rectifiers
- Measurement and Analysis of Ripple
and Noise
- Precompliance Testing to IEC Standard EN61000-3-2,
EN61000-3-2 AM14 and MIL Standard 1399 (400 Hz)
- Debugging
Active Power Factor Correction circuits
Product
Description
TDSPWR3 power measurement and analysis software
transforms Tektronix digital oscilloscopes into sophisticated analysis
tools that quickly measure and analyze power dissipation in power
supply switching devices and magnetic components, and then generates
detailed test reports in customizable formats. TDSPWR3, used with
a Tektronix TDS5000B, TDS7000/7000B, CSA7000 Series or TDS6000B models
oscilloscope and differential voltage and current probes, forms a
complete measurement system for power supply design and test.
To improve the efficiency of switching power supplies with increased
power densities, designers need to analyze power dissipation and characterize
transitions at higher switching frequencies. Using TDSPWR3’s unique
switching loss and B-H analysis features, you can measure switching
and magnetic device power dissipation with a touch of a button. Tektronix
oscilloscopes’ high bandwidth, high sample rate and deep memory, combined
with the TDSPWR3, enable you to efficiently and accurately characterize
switching power supplies by measuring power loss at the switching
device and magnetic component. Reliability at the component level
of the switching power supply can be analyzed using Safe operating
area with mask test capability and measuring the peak flux density.
With the current harmonic standard (EMC) being imposed worldwide
to maximize the efficiency of the existing total generation capacity,
compliance to the IEC EN61000-3-2, EN61000-3-2 AM14 is critical. Reduce
your development and testing time by using the precompliance testing
capability of TDSPWR3 to test power supply designs to these standards
from your bench.
TDSPWR3 enables you to set units and scale
factor for Tektronix current and voltage probes to read the result
in the right unit. Automated deskew capabilities help you to get accurate
results.
Characteristics
Power Device Analysis - Switching Loss, HiPower Finder, B-H Analysis, Magnetic Loss, Inductance,
Maximum Magnetic Flux Density, Permeability, Remanence Flux Density,
Coercive Force, Total Loss*1, Safe Operating Area (SOA),
Gated SOA, SOA Mask Editor with Mask Testing, Dynamic On Resistance,
di/dt, dv/dt.
Line Power Measurements - True Power,
Apparent Power, Power Factor, Crest Factor, Current Harmonic, THD,
Precompliance testing for EN61000-3-2, EN61000-3-2 AM14 standard and
MIL standard 1399 (400 Hz).
Output Measurement - Ripple
due to line frequency and switching frequency, Turn on time.
Modulation Analysis - Pulse Width, Duty Cycle, Period, and
Frequency variation vs. Time.
Spectral Analysis - Automated
Spectral analyses by setting start frequency, stop frequency, and
resolution bandwidth.
Report Generation - Create template,
custom report layout, and report generation.
Deskew - Automatic.
*1 Total loss measurement needs four
channels; it is not supported in TDS5032B or TDS5052B.
Tektronix
Oscilloscopes and Probes Supported
TDS5000B Series Digital
Phosphor Oscilloscopes - TDS5032B, TDS5034B, TDS5054B, TDS5054BE,
TDS5052B, TDS5104B.
TDS7000/7000B Series Digital Phosphor
Oscilloscopes - TDS7054, TDS7104, TDS7154B*2, TDS7254B*2, TDS7404B*2.
CSA7000 Series Communications
Signal Analyzer - CSA7154*2, CSA7404*2
TDS6000B Models Digital Storage Oscilloscope - TDS6404B*2, TDS6604B*2
Current Probes - TCP202,
TCPA 300 with TCP312, TCP305, TCP303, TCPA400 with TCP404XL, AM503B
with A6312, A6302, A6303, P6021, or P6022
Differential
Probes - P5205, P5210, P5200 and ADA400A
Deskew Fixture
- 067-1478-00
Probe Adapter - TCA-1MEG, while using
with TDS6000B/CSA7000/TDS7154B/TDS7254B/TDS7404B
*2 A TCA-1MEG TekConnect 1 MΩ buffer amplifier is required to use a
1 MΩ differential probe with the TDS7154B/TDS7254B/TDS7404B, TDS6000B
models, and CSA7000 Series oscilloscopes.