TLA700 Series Upgrade Guide
TLA700 Series
|
What’s new
for the TLA700 Series Tektronix logic analyzers
Hardware
- Four
new TLA7NAx Series logic analyzer modules offering 125 ps (8 GHz) MagniVu™
acquisition simultaneous with 500 ps (2 GHz) timing and up to 450 MHz State,
with up to 128 Mb Record Length.
-
125 ps (8 GHz) MagniVu™
Timing - acquisition on all channels with 16 Kb record length per channel.
Users can view any channel with 125 ps timing resolution to verify digital
signal timing. Additional capabilities include adjustable MagniVu sample rate
(125 ps to 1 ns), movable trigger position and a separate MagniVu trigger
action that can be triggered independent of the main trigger.
-
500 ps
(2 GHz) Timing - acquisition with up to 128 Mb record length on quarter-channels
to capture elusive digital signal timing problems over long time spans. 1 GHz
timing at up to 64 Mb record length is available on half-channels and 500 MHz
timing is provided on all channels at up to 32 Mb record length.
-
450/235 MHz
State - acquisition that enables tracing data flow and program execution
of processors and buses. A setup/hold window of 625 ps provides accurate data
capture from fast processors and buses. This window position is adjustable
in 125 ps increments within a range from –16 ns to +8 ns.
-
512 kb,
2 Mb, 8 Mb, and 32 Mb Record Length - enables triggering on the symptom
of a problem and capturing the cause when widely separated in time. Record
length configurations of 512 kb, 2 Mb, 8 Mb, and 32 Mb are available. Using
Internal 2X and Internal 4X clocking, all instruments can trade channels for
record length for up to 128 Mb record length on quarter-channels (using a
32 Mb instrument).
-
More Triggering Resources - enable triggering
on elusive problems in designs. 16 trigger states, 16 word recognizers, 4
range recognizers, 16 edge/transition recognizers, 2 timer/counter, snapshot
recognizer, setup/hold violation triggering, and glitch trigger.
- The P69xx
Series logic analyzer probes use the new D-Max™ technology that maximizes
channel density for the most challenging applications where board space is
at a premium. These new probes utilize an industry tested cSpring (cLGA™)
attached mechanism that provides a durable, reliable mechanical and electrical
connection between the probe and the circuit board. The P6960 probes have
a lead set Option 01 that enables general-purpose probing. With industry leading
0.5 pF input capacitance the P69xx probes will minimize probe loading on your
signals. When coupled with the iCapture™ capability of a TLA7Axx module, the
P69xx probe and module combination provides an oscilloscope with a 2 GHz analog
bandwidth high-density probing solution.
-
P6960 - 34-channel
high-density compression logic analyzer probe with D-Max™ technology; single-ended
data, differential clock compatible with TLA7Axx and TLA7NAx logic analyzer
modules.
-
P6980 - 34-channel high-density compression logic
analyzer probe with D-Max™ technology; differential data/clock compatible
with TLA7Axx and TLA7NAx logic analyzer modules.
Software
-
iLink™
Tool Set – Quickly and easily find and characterize elusive analog and
digital problems with the iLink toolset. The iLink toolset includes:
-
IConnect™
– simultaneous analog and digital acquisition through a single logic analyzer
probe.
-
iView™ – displays automatically time-correlated analog
and digital data on a single logic analyzer display.
-
iVerify™
– enables multi-channel analysis and validation using high-resolution
oscilloscope-generated eye diagrams.
-
Filter/Color – Show,
hide, or color data in listing or waveform windows based on Boolean clause
definitions (AND and OR) using channel, group, sample, or timestamp values.
Capability also supports filtering on disassembly mnemonic values and text
values. Filtering process is “filter-on-demand” which saves time when filtering
large memory captures. When an acquisition is complete the application only
filters what is displayed, instead of making you wait minutes while the entire
memory is processed. Then, when the data window is scrolled, it continues
to filter what is displayed. Create multiple filter definitions and manager
filters within the application. Filter definitions can also be shared across
TLA setup files through the “load filter” capability. Filters can also be
saved for use later through the “save filter” mechanism. Filter/color capability
is fully compatible with TLAVu.
-
Enhanced Search – More powerful
search capability using Boolean clause definitions (AND and OR) using channel,
group, sample, timestamp values, or event duration. Capability also supports
searching on disassembly mnemonic values, text values, glitches, setup/hold
violations, and qualification gaps. Search across multiple data sources using
“DataSource1 OR DataSource2” capability. Load/save search definitions. Quickly
change between search definitions using drop down menu of most recently used
search definitions. Enhanced search capability is fully compatible with TLAVu.
-
Graph
Window – New type of data window added to the “Add Data Window” wizard.
Allows graphing of multiple data series. Individual display properties for
each series allow users to customize their display by choosing different data
point indicators, colors, and line styles. Flexible axis definitions including
time, sample number, group value, row/line number, and timestamp. Cursors
with readouts and lock cursor/window controls. Marks to locate key data in
a graph. Supports normalized data ranges. Works with filtered data so users
can remove gaps in data and graph data by filtered sample number. Color grading
to graphically represent hit frequency. Zoom controls to allow users to zoom
in or zoom out on graph data. Graph window is fully supported with TLAVu.
-
AutoDeskew
– New capability that automates deskew and verification of logic analyzer
setup/hold windows. Adjustments can be made per channel. Allows custom clock
setups and users can utilize different setup/hold settings for each type of
clocking. Setup/hold violation analysis capability allows users to test for
violations occurring with current setup/hold settings. Test results display
number of violations. Duration of test is user selectable. Users have the
ability to automatically convert a test setup to a trigger setup for use by
the logic analyzer trigger system. This would allow a user to determine exactly
which channels may be failing their setup/hold requirements. This capability
works with all TLA600 instruments, TLA7Nx/Px/Qx, and TLA7Axx modules.
-
iVerify™
– Utilizes a TDS5/6/7000 or CSA7000 oscilloscope to capture eye diagrams
for display and analysis on a TLA logic analyzer. Works with TLA7Axx logic
analyzer modules. Quickly generate high-resolution eye diagrams for multiple
channels. Measurements provided on the logic analyzer include horizontal and
vertical histograms, 4-point and 6-point polygon masks (including upper/lower
masks), slope measurements, eye-opening measurements, and statistical measurements
(min, max, mean, std deviation, peak-to-peak, voltage level, number of hits,
eye height, eye width). Supports viewing data in bus form (aggregate) or individual
channels. Highlight individual channels in a bus form.
-
TPI.NET
– New remote programming functionality using .NET-programming interfaces.
This provides a wider choice of development languages. With .NET, component
developers can use any language that supports .NET – VC++, C#, VB, and others.
By comparison COM/DCOM component developers were limited to the languages
that the TLA explicitly supported, VC++ and VB. .NET also provides increased
developer productivity. The .NET development environment is significantly
more productive than the current COM development environment. In other words,
it is a lot easier for a third party developer to create a .NET component
than it is to create a COM component. TPI.NET will provide increased instrument
control, including more trigger and setup control, more compare and repetitive
control. COM/DCOM will continue to be supported with existing capabilities.
No new commands have been added to COM/DCOM support.
-
Protocol
Display Window and Protocol Designer – Protocol Display is a new data
window to be added to the “Add Data Window” wizard. Display window provides
traditional three-paned protocol view; packet overview, packet decode, and
hex data. Filter data on protocol field values. View packet data across multiple
protocols. Protocol Designer allows you to define or modify your own protocol
and stack definitions.
-
Multi-language Windows 2000 Professional
– Delivered standard with the TLA. This new version of Windows 2000 Professional
with Service Pack 3 will allow the Windows graphical user interface to be
shown in a native language. Also provides fonts for localized applications.
Supports 31 local languages.
-
Import/Export Channel and Group
Definitions – Import from file or export to file channel names and group
definitions. Exports to a text file the current LA channel names and groups.
Edit this file with the text editor of your choice, and then import the edited
channel names and groupings back in from the modified file.
-
EasySetup
Wizard – New wizard to quickly show timing waveforms of your signals.
Improve your time-to-data by allowing the logic analyzer to do the setup work
for you.
-
Zoom Immediate – User definable preferences to dictate
how click-n-drag zoom box operates. Selections include zoom immediate, display
context menu, show rectangle.
-
DSO Channels have TDS Colors – The
default DSO colors in the TLA waveform display will now match those on the
TDS oscilloscopes – Ch 1 (yellow), Ch 2 (blue), Ch 3 (green), Ch 4 (magenta).
-
Microsoft
Windows Colors – The color definition for fonts, backgrounds, waveform
colors, and other color definitions will now follow the traditional Windows
color selection.
-
LA Setup Toolbar – Streamlined view of logic
analyzer setup controls that is organized for faster access to key setup components.
-
Tools
Toolbar and Menu Item – New toolbar dedicated to displaying toolbar buttons
for tools. The toolbar contains the same things that are displayed in the
new Tools menu of the menu bar. Users can decide to turn this toolbar on or
off.
-
Highlight Channel Names – A new capability to find and
highlight channel names in the logic analyzer setup window. This will help
users quickly and easily locate channel names among hundreds of names in the
setup window.
-
Rename Channel/Group from Data Window – Use
a context menu to select “Rename” directly from the data window instead of
having to rename the channel/group from the setup window.
-
User-defined
Default Waveform Height – This will allow users to modify the default
waveform height in the waveform display.
-
Support for LA Status
Channels – Provides display of logic analyzer status channels in the listing
display. These status channels include trigger state, allowing users to view
what state the trigger machine was in when each sample was acquired.
-
Per
Channel Clock and Setup/Hold Violation Definition – Clocking setup parameters
are now selectable by channel rather than by group. Program setup/hold violation
detectors by channel rather than by group.
-
Merge Modules with
Different State Speeds – Enables merging of modules with different state
speeds. When modules with different state speeds are merged, the merged set
will operate at the state speed of the module with the slowest state speed
setting.
-
Version 4.4 TLA Application Software – Newest version
of TLA700 application software. Version 4.4 requires Windows 2000 Professional
with Service Pack 4. Your existing TLA714/715/720/721 can easily be upgraded
to Version 4.4 with the appropriate TLA7UP Field Upgrade Kit. Version 1.6
of the PatGen Application Software and PatGenVu are also included.
-
Version
1.6 PatGen Application Software – Newest version of the TLA7PG2 pattern
generator application. Version 1.6 PatGen Application Software is available
either as part of the Version 4.4 TLA Application Software or on the Web (primarily
for TLA704/711 and TLA714/720 users who have Windows 98 and Version 3.2 TLA
Application Software).
Protect Your Investment By Moving Forward
with Tektronix
Tektronix is committed to continually introducing new
mainframe capabilities, new instrument modules and software features for the
TLA family of logic analyzers. The following tables give an overview of the
current TLA mainframe capabilities and the current TLA software versions.
Current
TLA Mainframe Capabilities
The table below reflects the latest TLA
mainframe capabilities:
|
Characteristic
|
TLA715
|
TLA721
|
|
CPU Type
|
Pentium III
|
Pentium III
|
|
Chipset
|
i815E
|
i815E
|
|
DRAM
|
512 MB
|
512 MB
|
|
Hard Disk
|
40 GB Replaceable Standard
|
40 GB Replaceable Standard
|
|
Second Hard Disk Available
|
Yes - 40 GB Fixed Optional
|
Yes - 40 GB Fixed Optional
|
|
Internal Display Resolution
|
800x600
|
None - requires external display
|
|
External Display Resolution
|
1600x1200 with 2 outputs
|
1600x1200 with 2 outputs
|
|
CD-RW
|
Yes - Internal
|
Yes - Internal
|
|
PC Card Support
|
32-bit PC Card
Two Type II/One Type III
|
32-bit PC Card
Two Type II/One Type III
|
|
USB Ports
|
Two
|
Two
|
|
10/100 Mb LAN
|
Yes
|
Yes
|
Current TLA Software Versions
The table below reflects
the latest software version numbers for each of the TLA application software
components:
|
TLA Software Component
|
TLA Application Software Release
|
|
TLA Application SW
|
4.4
|
|
TLA Application
|
4.4.075
|
|
TLA7Axx FW
|
4.4.005
|
|
TLA7NAx FW
|
4.4.005
|
|
TLA7N/P/Qx FW
|
4.3.14
|
|
TLA7L/Mx FW
|
3.2.1
|
|
TLA7D/Ex FW
|
3.1.1
|
|
TLA6xx FW
|
4.3.15
|
|
TLA520x FW
|
4.4.001
|
|
MF Diagnostics
|
4.4075
|
|
Firmware Loader
|
4.4075
|
|
TLAScript
|
4.4075
|
|
TLASym
|
4.4075
|
|
TPI Client SW
|
4.4075
|
|
TLAVu
|
4.4075
|
|
PatGen App SW
|
1.6.011
|
|
PatGen FW
|
2.0.1
|
|
PPI Client SW
|
1.6.011
|
|
PatGenVu
|
1.6.011
|
|
Windows 2000 SP4
|
5.00.2195
|
|
Windows 2000 SP3
|
N/A
|
|
Windows 2000 SP2
|
N/A
|
|
Windows 2000 SP1
|
N/A
|
|
Microsoft Windows 98
|
N/A
|
|
Microsoft Windows 95
|
N/A
|
|
QA+Win32
|
N/A
|
|
SnagIt
|
7.0.0
|
|
Logitech Mouseware
|
9.76
|
|
CheckIt Utilities
|
7.0
|
|
NI-488.2
|
2.1
|
|
NI-MAX
|
2.2.0
|
|
RecordNow Max
|
4.50
|
|
Adobe Reader
|
6.0
|
|
Flash Player
|
6.0.79.0
|
|
TLA715/721 BIOS
|
1.00.02
|
|
TLA714/720 BIOS
|
2.03.11
|
|
TLA704/711 BIOS
|
N/A
|
|
TLA600 BIOS
|
P9-0009
|
|
TLA5000 BIOS
|
0040.P16
|
What Upgrades Are Available For My TLA714/715/720/721 Logic
Analyzer?
The TLA family of logic analyzers have a variety of upgrade
paths to assist you in protecting your TLA investment. The chart below shows
you the many ways that you can upgrade your current TLA and refers you to
the appropriate section in the remainder of this TLA Upgrade Guide:
|
New Capability Desired
|
You Currently Own
|
Please Refer to Section
|
|
Add More DRAM & Larger HDD
|
TLA714/715/720/721
|
TLA7UP Mainframe Field Upgrade Kits
|
|
Add New User Interface and Operating System SW Features
|
|
Add New iView External Oscilloscope Capability
|
|
Add New Measurement Modules to Existing TLA714/715/720/721 Mainframe
|
|
Add New Expansion Mainframe to Existing TLA714/715/720/721 Mainframe
|
|
Upgrade Logic Analyzer State Speed or Record Length
|
TLA7Lx/Mx, TLA7Nx/Px/Qx, TLA7Axx, TLA7NAx
|
PowerFlex™ Upgrade Kits
|
|
Upgrade Pattern Generator Record Length
|
TLA7PG2
|
|
Utilize TLA Family Software Support Library
|
|
TLA Family Software Support User Library
|
|
Latest TLA Family Documentation
|
Any TLA logic analyzer
|
TLA Family Documentation
|
Applications Support and Training
Tektronix has
a wealth of resources that can help you maximize the utilization of your TLA
logic analyzer. In the field, we have a team of applications engineers who
you can talk with or have them visit your site to discuss your application,
all at no charge. We also have a team of very experienced applications engineers
in our Tektronix Technical Support Center that can be reached either by phone
or e-mail:
- Inside US: 1-800-TEK-WIDE (1-800-835-9433, ext. 2400)
(6AM-5PM PST)
- Outside US: (503) 627-2400 (6AM-5PM PST)
57W-17065-0b, 02-MAY-2008
|
|
 |