Features & Benefits
- Quickly Obtain S-parameters
using Your TDR Oscilloscope
- Differential, Single Ended,
Mixed Mode; Insertion, Return Loss, Frequency-domain Crosstalk
- PCI Express, Serial ATA, HDMI, Infiniband, Gigabit Ethernet,
Manufacturing and Standard Compliance Testing Including Eye Mask Tests
- Simplified Calibration Procedure Minimizes Human Errors and
Makes Fixture De-embedding a Simple Task
- Intuitive, Easy,
and Accurate for Serial Data, Gigabit Digital Design, and Signal Integrity
- Gain Insight into Interconnect Link Performance through
Synthesized Eye Testing
- Apply Industry Standard (PRBS,
CJTPAT, K28.5, HDMI, etc.) or User-specified Stress Patterns
- Model Effect of Transmitter and Receiver Equalization on Signal Impairment
- Simulate Real-World Signals through Jitter and Noise Insertion
- Measure Computed BER, Eye Opening, Jitter and Noise and do BER
Mask Testing at Any Point Along the Data Link
- Easily
Analyze Sources of Interconnect Jitter, Losses, Crosstalk, Reflections,
and Ringing
- Analyze Interconnects Concurrently in Time
and Frequency Domains
- Quickly Perform Interconnect Link Analysis
and Ensure System-level Simulation Accuracy
- Obtain
More Accurate Impedance and S-parameter Measurements
- Enhanced TDR Resolution using Industry-best TDR Performance and Z-Line
Multi-reflection Impedance Deconvolution Algorithm
- Supports
Enhanced Accuracy TDR Acquisition for Higher SFDR
- Fast and
Easy Package and PCB Trace Failure Location
- 50 Ω Calibration
Eliminates the Need for Time-consuming Normalization
- Automate your Manufacturing Test and R&D Measurements with Scripts
and Programmatic Control
- Command-line Interface for
Many Functions (S-parameters, Z-Line, Others)
- Efficiently
Model PCBs, Flexboards, Connectors, Cables, Packages, and Sockets
- Topological and Behavioral, Measurement Based, Frequency
Dependent, Exact SPICE Models
- Automatically Convert TDR/T
or VNA Data into SPICE with MeasureXtractor; Model Passivity, Stability,
Causality Guaranteed
- Optimized for Use with DSA8200
Digital Serial Analyzer Sampling Oscilloscope with 80E10, 80E08, and
80E04 True Differential TDR Modules
Applications
- High-speed PCB, Cable Assembly,
Connector, and IC Package Testing
- Serial Data Network Analysis
- Compliance Test for SATA, PCI Express, FB-DIMM, HDMI, Fibre
Channel, Ethernet, and Other Serial Data Standards
- Consumer
Electronics Testing
- Communications Testing
- Computer
Testing
Software
for Efficient Evaluation of Gigabit Interconnect Links and Devices
As clock speeds and rise times of digital circuits increase,
interconnect signal integrity dramatically affects digital system
performance. Accurate and efficient analysis of the interconnects
in time and frequency domains is critical to predict signal losses,
jitter, crosstalk, reflections and ringing, digital bit errors, and
eye-diagram degradation, and ensure reliable system operation.
IConnect® software is the efficient, easy to use,
and cost-effective solution for measurement-based performance evaluation
of gigabit interconnect links and devices, including signal integrity
analysis, impedance, S-parameter, and eye-diagram tests and fault
isolation. With the help of IConnect and the built-in IConnect Linear
Simulator, you can complete interconnect analysis tasks in minutes
instead of days, resulting in faster system design time and lower
design costs.
The Easiest Way to Perform Interconnect S-parameter
Measurements for Serial Data Network Analysis Applications
IConnect® S-parameters is the efficient and easy-to-use
tool for digital designers, operating at gigabit speeds, to perform
single-ended, differential, and mixed-mode S-parameter measurements
of interconnects, measure insertion loss, return loss, and frequency-domain
crosstalk, and conduct interconnect electrical standard compliance
testing.
Efficiency
Operating on the DSA8200 TDR platform,
IConnect S-parameters is the most cost-effective and highest throughput
approach for S-parameter measurements in digital design, signal integrity
analysis, and interconnect compliance testing. It provides as much
as a 50% cost savings compared to similar bandwidth VNAs, and dramatically
speeds up measurements. You can also take advantage of the IConnect
S-parameters command-line interface to add S-parameter measurements
to the overall suite of manufacturing tests you perform using your
TDR instrument.
Calibration and Measurement Simplicity
The simplicity of S-parameter calibration using a reference (open,
short, or through) and an optional 50 Ω load make the measurement
itself, fixture de-embedding, and moving the reference plane a snap.
Calibration simplicity minimizes human errors during the measurement.
Touchstone file format output enables easy S-parameter file sharing
for further data analysis and simulations.
With the addition
of the IConnect® S-parameter Wizard, calibration and acquisition
of one to four-port single-ended and differential S-parameters is
even easier. This “mini-application” guides the user through setup,
calibration (including channel deskew) and acquisition of S-parameters
and automatically generates Touchstone files for one or multiple DUTs.
Performance
Tektronix offers several true differential
TDR modules, which in combination with IConnect allow S-parameters
measurements with up to -70 dB of dynamic range. This performance
is suitable for serial data analysis, digital design, and signal integrity
applications, resolving better than 1% (-40 dB) of crosstalk, and
electrical compliance test masks that typically call for the measurements
in the -10 to -30 dB range. The table below summarizes the performance
characteristics of these true differential TDR modules. Adding a wider-bandwidth
module on the receiver end (e.g., using an 80E09 as a receiver with
an 80E10 as a stimulus) will ensure the highest bandwidth for insertion
loss measurements.
Performance Characteristics ofTrue Differential TDR Modules
|
Module
|
Typical Rise Time
|
S-parameter Bandwidth
|
|
Incident
|
Reflected
|
|
80E10
|
12 ps
|
15 ps
|
50 GHz
|
|
80E08
|
18 ps
|
20 ps
|
30 GHz
|
|
80E04
|
23 ps
|
28 ps
|
20 GHz
|
With the long record length acquisitions, IConnect® provides great flexibility for obtaining the desired frequency
range and frequency step when performing S-parameter measurements.
Up to 1,000,000 points can be acquired*1.
*1 Long record lengths are supported only on DSA8200, CSA/TDS8200,
and CSA/TDS8000 platforms.
Enhanced Accuracy TDR
Release
5.0 of IConnect® supports a new acquisition mode for the
DSA8200 – Enhanced Accuracy TDR (EA TDR). In this mode of operation
TDR Timebase non-linearity as well as test setup deterministic noise
and jitter effects are minimized; further improving the Spurious-Free
Dynamic Range (SFDR) for TDR and S-parameter measurements. While this
improvement applies to all devices under test, its benefit will be
most noticeable when testing long interconnects using long record
length acquisitions.*2
*2 EA TDR operation
requires a Tektronix DSA8200 with appropriate hardware support (a
DSA8200 with serial number > B030000 or one with the DSA82EFEUP upgrade
kit applied.)
Efficient and Easy Interconnect Signal Integrity
Analysis and SPICE Modeling
IConnect software allows you to
quickly and easily generate SPICE and IBIS models for your PCBs, flexboards,
connectors, cables, packages, sockets, and I/O buffer inputs directly
from TDR/T or VNA S-parameter measurements. IConnect allows you to
rapidly analyze eye-diagram degradation, jitter, loss, crosstalk,
reflections, and ringing in your digital system. IConnect Linear Simulator
allows you to link several interconnect components together to evaluate
the total time, frequency-domain performance, and eye diagram of the
overall channel. IConnect® substantially simplifies the
signal integrity analysis of the interconnect link, equalization and
emphasis component design, and analysis of the interconnect link with
transmitter and receiver.
Package, Socket, and Connector Designers
IConnect provides the capability to quickly and easily compute
your package, socket, and connector L and C using either the JEDEC
or IBIS industry-standard computation procedure, the IConnect MeasureXtractor
automatic modeling tool, or additional differential and single-ended
TDR modeling procedures. To measure the input or output capacitance
of the IC I/O buffer, the same modeling procedures can be applied.
These JEDEC L and C measurements can also be automated in manufacturing
using the IConnect command line interface.
Cable and Connector
Manufacturers
IConnect® offers the fastest, most
cost-effective eye mask, insertion and return loss, and frequency-domain
crosstalk specification compliance testing. The S-parameter compliance
test can be performed in manufacturing using the IConnect command-line
interface. Eye mask testing allows you to include the effects of crosstalk
on the eye. In addition, IConnect has the capability to easily extract
models that include skin effect and dielectric loss, insertion and
return loss, eye-diagram degradation, and frequency-dependent RLGC
parameters, and analyze the effect of equalization and pre-emphasis
on cable assembly performance.
Designers of Large Computer
and Server Motherboards and Communications Backplanes
Backplane
and motherboard designers can analyze the signal integrity performance
of their board, connector, and package interconnects in detail, or
predict the eye-diagram degradation in the interconnects due to frequency-dependent
transmission line losses and crosstalk using either the built-in links
to SPICE simulators, or the IConnect Linear Simulator.
MeasureXtractor™:
The Fastest Way from TDR/T or VNA Measurements to Simulations
MeasureXtractor is an automated model extraction tool, allowing
you to obtain an accurate measurement-based SPICE model of the interconnect,
with the press of a button. MeasureXtractor will guide you through
the data acquisition process, help you acquire TDR/T or VNA S-parameter
data, and will automatically produce an accurate model that matches
both the time and frequency response of your interconnect.
Losses, dispersion, jitter, crosstalk, reflections, and ringing are
predicted accurately, up to the highest frequency of operation of
your instrument. Passivity of models must be explicitly enforced during
model extraction, and MeasureXtractor model passivity is assured through
proprietary algorithms. This means that interconnect models generated
with MeasureXtractor™ will not artificially amplify the signal, oscillate,
or produce noncausal results when used in system-level simulations.
MeasureXtractor produces what is known as a behavioral model.
Such a model does not take into account the actual topology of the
interconnect, but instead accurately represents the time and frequency
behavior of the interconnect in the most simulation-efficient manner;
in the case of MeasureXtractor with the minimum number of components
and with guaranteed passivity.
Comparison of Behavioral
andTopological Modeling Approaches
|
Characteristic
|
Behavioral
|
Topological
|
|
Measurement Requirements
|
Requires full-port measurement
|
Just TDR (reflection) may be sufficient
|
|
Topology Selection
|
Automatic,
no user intervention
|
User-controlled (easy and intuitive from TDR measurements)
|
|
Model Extraction
|
Automatic,
no user intervention
|
User-driven; more labor intensive and requires more skill
|
|
Type of Models
|
“Black-box”, no internal changes allowed
|
Intuitive, topology correlates to model
|
|
Limitations
|
Large model size for long interconnects (backplanes, cable
assemblies)
|
Efficient model extraction processes exist for large lossy
interconnects
|
|
Application
|
Quick inclusion of S-parameter or TDR/T measurements into
simulation; the “do-it-all” modeling tool
|
Comprehensive modeling, “what-if” scenarios analysis, signal
integrity troubleshooting, and fault finding
|
Efficient and Easy Signal Integrity Modeling and
Design Validation
IConnect Simulate-and-Verify
IConnect® TDR and S-parameter software
provides you with an integrated simulate-and-compare link between
SPICE simulators, and TDR or S-parameter measurements, allowing you
to quickly validate models produced by IConnect or by outside tools,
such as field solvers. You can validate your own models for your board-trace,
package, or connector, or the models provided by your vendor. The
whole design can be validated using an external SPICE simulator or
IConnect Linear Simulator, ensuring that your design works reliably
and the eye diagram is within specifications.
The Accurate
Way to Measure Impedance
IConnect Z-Line vs. TDR
IConnect® software uses an impedance deconvolution
(Z-Line) algorithm, which further enhances the impedance computation
feature in the DSA8200. The Z-Line algorithm efficiently takes care
of multiple reflections in the TDR impedance measurement and produces
the True Impedance Profile. As a result, you can measure PCB trace
impedance more accurately and improve correlation of your data between
measurements, including the correlation between such measurements
performed by your coworkers or customers in another part of the world.
The True Impedance Profile produced by IConnect Z-Line allows you
to improve not only the TDR oscilloscope impedance measurement accuracy,
but also to increase the TDR oscilloscope resolution. The EZ Z-Line
user interface, providing single-button Z-Line computation for any
number of waveforms, and enabling easy waveform manipulation and analysis,
makes TDR data much easier to interpret.
Package and Board
Failure Analysis with TDR
TDR is a reliable nondestructive
approach for locating the position of failures in BGA and similar
packages and printed circuit boards. IConnect software Z-Line algorithm
improves the resolution of TDR, facilitating easier location of open
and short faults. When IConnect Z-Line algorithm is used with the
80E10 TDR module with 12 ps incident TDR rise time it enables sub-millimeter
resolution for package and on-chip failure analysis. IConnect® EZ Z-Line user interface is specifically designed with a
failure analyst in mind, providing single-button Z-Line computation
for any number of waveforms, and quick and easy comparison between
known good device traces and pins and suspect devices. This makes
the TDR data much easier to interpret. Finding the location of open
faults and signal-to-ground shorts becomes a simple task, and finding
location of plane-to-plane shorts, signal-to-signal shorts, resistive
shorts, and faults in fan-outs become realistic tasks.
Feature Summary
|
Feature
|
80SSPAR
|
80SICON
|
80SICMX
|
|
Long Records (up to 1,000,000 points)
|
X
|
X
|
X
|
|
Z-Line
|
X
|
X
|
X
|
|
L-C Readouts
|
X
|
X
|
X
|
|
50 Ω Calibration (not required)
|
X
|
X
|
X
|
|
S-parameters
|
X
|
X
|
X
|
|
True differential
|
X
|
X
|
X
|
|
Flexible calibration: short, open or thru
|
X
|
X
|
X
|
|
50 Ω calibration (not required)
|
X
|
X
|
X
|
|
Amplitude and phase display
|
X
|
X
|
X
|
|
Touchstone (SnP) file export
|
X
|
X
|
X
|
|
L and C Computation using JEDEC Method
|
X
|
X
|
X
|
|
Command Line Interface to Z-Line, S-parameters, L-C Computation,
Step Spectrum, Eye Diagram and Compliance Testing
|
X
|
X
|
X
|
|
Eye Diagram
|
|
X
|
X
|
|
From TDR/T or S-parameters
|
|
X
|
X
|
|
From SPICE models
|
|
X
|
X
|
|
Eye diagram with crosstalk effects
|
|
X
|
X
|
|
Industry-standard or user-specified data patterns
|
|
X
|
X
|
|
Transmitter and receiver equalization
|
|
X
|
X
|
|
Jitter/Noise insertion
|
|
X
|
X
|
|
BER, jitter, noise measurements
|
|
X
|
X
|
|
BER eye mask testing
|
|
X
|
X
|
|
Automatic mask shift to fit asymmetric eyes
|
|
X
|
X
|
|
Eye-diagram Compliance Tests for HDMI, PCIe, and SATA Standards
|
|
X
|
X
|
|
Auto jitter to close transmitter eye
|
|
X
|
X
|
|
Standard specified patterns
|
|
X
|
X
|
|
Standard specific equalization
|
|
X
|
X
|
|
Step Spectrum
|
|
X
|
X
|
|
Topological Modeling
|
|
X
|
X
|
|
Lossy and lossy coupled
|
|
X
|
X
|
|
Z-Line/Lossless, lumped, or distributed
|
|
X
|
X
|
|
Complete topological modeling system
|
|
X
|
X
|
|
PSpice, HSpice, and Berkeley SPICE3 Output Formats
|
|
X
|
X
|
|
Integrated Link to Simulators
|
|
X
|
X
|
|
IConnect Linear Simulator
|
|
X
|
X
|
|
Behavioral Modeling (MeasureXtractor)
|
|
|
X
|
|
Fully automatic modeling, no user intervention
|
|
|
X
|
|
Use TDR/T or VNA S-parameter data for modeling
|
|
|
X
|
|
Model concurrently in time and frequency domains
|
|
|
X
|
Ordering Information
80SSPAR
IConnect® S-parameter and Z-Line software.
Includes: First year of maintenance and support from date of purchase.
80SICON
IConnect® Signal Integrity TDR and S-parameter
Software.
Includes: First year of maintenance and support
from date of purchase. 80SICON includes all 80SSPAR functionality.
80SICMX
IConnect® and MeasureXtractor™ Signal
Integrity TDR and S-parameter Software.
Includes: First
year of maintenance and support from date of purchase.
80SICMX includes
all 80SICON functionality plus MeasureXtractor (also includes all
80SSPAR functionality).
Standard options to 80SSPAR,
80SICON, and 80SICMX
|
Option
|
Description
|
|
Opt. USB
|
USB hardware key (dongle)
|
|
Opt. PPD
|
Parallel port hardware key (dongle)
|
Standard IConnect Extensions toExisting Maintenance Agreements
|
Option
|
Description
|
|
80SSPAR SWS1
|
Extend 80SSPAR maintenance agreement by 1 year
|
|
80SSPAR CUR
|
Renew an 80SSPAR license that is out of support – contact
your account manager or product line to obtain pricing
|
|
80SICON SWS1
|
Extend 80SICON maintenance agreement by 1 year
|
|
80SICON CUR
|
Renew an 80SICON license that is out of support – contact
your account manager or product line to obtain pricing
|
|
80SICMX SWS1
|
Extend 80SICMX maintenance agreement by 1 year
|
|
80SICMX CUR
|
Renew an 80SICMX license that is out of support – contact
your account manager or product line to obtain pricing
|
Upgrade Options
|
Option
|
Description
|
|
Upgrade to 80SICON
|
|
80SSPARUP
|
Upgrade from 80SSPAR to 80SICON
|
|
Opt. ICONUSB
|
Add USB hardware key (dongle)
|
|
Opt. ICONPPD
|
Add parallel port hardware key (dongle)
|
|
Upgrade to 80SICMX
|
|
80SICMX
|
Upgrade from 80SSPAR to 80SICMX
|
|
Opt. ICMXUSB
|
Upgrade with USB hardware key (dongle)
|
|
Opt. ICMXPPD
|
Upgrade with parallel port hardware key (dongle)
|
|
80SICONUP
|
Upgrade from 80SICON to 80SICMX
|
|
Opt. ICMXUSB
|
Upgrade with USB hardware key (dongle)
|
|
Opt. ICMXPPD
|
Upgrade with parallel port hardware key (dongle)
|
Recommended Hardware Compatibility
- DSA8200, CSA/TDS8200, or CSA/TDS8000, with 80E10, 80E08, or 80E04
TDR sampling modules (local TekVISA interface is supported; install
and run directly on the instrument)
- P80318 – 18 GHz Differential
TDR Probe. 80A02 module recommended for static protection of each
channel of the sampling or TDR module.
- P8018 – 20 GHz Single-ended
TDR Probe. 80A02 module recommended for static protection of the sampling
or TDR module.
- 80A02 – EOS/ESD Protection Module (1 channel).
P8018 or P80318 TDR probe recommended.
Interconnect
Cables (3rd party)
Tektronix recommends using quality
high-performance interconnect cables with these high-bandwidth products
in order to minimize measurement degradation and variations. The W.L.
Gore & Associates' cable assemblies, accessible at www.gore.com/tektronix, are compatible with the 2.92 mm, 2.4 mm, and 1.85 mm connector
interface of the 80Exx modules. Assemblies can be ordered by contacting
Gore.
Calibration Kits and Accessories (3rd party)
To facilitate S-parameter measurements with these electrical
modules and IConnect software, we recommend precision calibration
kits, adapter kits, connector savers, airlines, torque wrenches, and
connector gauges from Maury Microwave. These components, accessible
at www.maurymw.com/tektronix.htm, are compatible with the 2.92 mm, 2.4 mm, and 1.85 mm connector
interface of the 80Exx modules. Cal kits and other components can
be ordered by contacting Maury Microwave.