Features & Benefits
- 40 MHz, 60 MHz, 100 MHz, and
200 MHz Bandwidths
- Sample Rates up to 2 GS/s Real Time
- 2 or 4 Channels
- Color or Monochrome LCD Display
- Removable Data Storage using the Front-panel USB Port
- Seamless PC Connectivity through the USB Device Port, with OpenChoice® and NI SignalExpress® PC Software
- Advanced
Triggers including Pulse Width Trigger and Line-selectable Video Trigger
- FFT Standard on All Models
- 12 Automatic Measurements
- Multiple-language User Interface and Context-sensitive Help
- Direct Print to all PictBridge®-compatible Printers
through the USB Device Port
- Lifetime Warranty*1
Applications
- Design and Debug
- Education and Training
- Manufacturing Test and Quality Control
- Service and Repair
TDS1000B
and TDS2000B Series Oscilloscopes
Instantly Productive. Incredibly
Easy.
The TDS1000B and TDS2000B Series digital storage oscilloscopes
deliver an unbeatable combination of performance and ease of use,
at a price you can afford.
*1 Limitations apply.
For terms and conditions, visit www.tektronix.com/lifetimewarranty.
Affordable Digital Precision
With up to 200 MHz
bandwidth and 2 GS/s maximum sample rate, no other color digital storage
oscilloscope offers as much bandwidth and sample rate for the price.
The TDS1000B and TDS2000B Series oscilloscopes provide accurate real-time
acquisition up to their full bandwidth, the same record length at
all time base settings, advanced triggers to isolate signals of interest,
and 12 standard automatic measurements on all models. Their Fast Fourier
Transform (FFT) and waveform add, subtract, and multiply math functions
allow you to analyze, characterize, and troubleshoot circuits.
Quick and Easy Waveform Capture
The simple user
interface with classic analog-style controls makes these instruments
easy to use, reducing learning time and increasing efficiency. Innovative
features such as the Autoset Menu, Probe Check Wizard, Context-sensitive
Help Menu, and color LCD display (TDS2000B Series) optimize instrument
setup and operation.
Flexible Data Transfer
With USB host and device ports which enable removable data storage,
seamless PC connectivity, and direct printing, no other color or monochrome
digital storage oscilloscope offers as much flexibility and ease of
data transfer for the price.
Simple Documentation and Analysis
Easily capture, save, and analyze measurement results with
OpenChoice PC Communications Software. Simply pull screen images and
waveform data into the stand-alone desktop application or directly
into Microsoft Word and Excel. To complement OpenChoice, National
Instruments SignalExpress Tektronix Edition Software provides you
with extended capabilities, including advanced analysis, remote oscilloscope
control, and live waveform analysis. Alternatively, if you prefer
not to use the PC, you can simply print your image directly to any
PictBridge-compatible printer using the USB device port.
Performance You Can Count On
Depend on Tektronix to provide
you with performance you can count on. In addition to industry-leading
service and support, every TDS1000B and TDS2000B Series oscilloscope
comes backed with a Lifetime Warranty*1 as standard.
*1 Limitations apply. For terms and conditions, visit
www.tektronix.com/lifetimewarranty.
Quickly and
easily capture waveforms.
Conveniently
use your USB flash drive to store screenshots and waveform data.
Easily capture, save, and analyze measurement
results with OpenChoice PC Communications Software.
Characteristics
TDS1000B and TDS2000B Series
Digital Storage Oscilloscopes
|
|
TDS1001B
|
TDS1002B
|
TDS1012B
|
TDS2002B
|
TDS2004B
|
TDS2012B
|
TDS2014B
|
TDS2022B
|
TDS2024B
|
|
Display (1/4 VGA LCD)
|
Mono
|
Mono
|
Mono
|
Color
|
Color
|
Color
|
Color
|
Color
|
Color
|
|
Bandwidth*2
|
40 MHz
|
60 MHz
|
100 MHz
|
60 MHz
|
60 MHz
|
100 MHz
|
100 MHz
|
200 MHz
|
200 MHz
|
|
Channels
|
2
|
2
|
2
|
2
|
4
|
2
|
4
|
2
|
4
|
|
External Trigger Input
|
Included on all models
|
|
Sample Rate on Each Channel
|
500 MS/s
|
1.0 GS/s
|
1.0 GS/s
|
1.0 GS/s
|
1.0 GS/s
|
1.0 GS/s
|
1.0 GS/s
|
2.0 GS/s
|
2.0 GS/s
|
|
Record Length
|
2.5K points at all time bases on all models
|
|
Vertical Resolution
|
8 bits
|
|
Vertical Sensitivity
|
2 mV to 5 V/div on all models with calibrated
fine adjustment
|
|
DC Vertical Accuracy
|
±3% on all models
|
|
Vertical Zoom
|
Vertically expand or compress a live or stopped
waveform
|
|
Maximum Input Voltage
|
300 VRMS CAT II; derated at 20 dB/decade
above 100 kHz to 13 Vp-p AC at 3 MHz
|
|
Position Range
|
2 mV to 200 mV/div +2 V; >200 mV to 5 V/div +50 V
|
|
Bandwidth Limit
|
20 MHz for all models
|
|
Input Coupling
|
AC, DC, GND on all models
|
|
Input Impedance
|
1 MΩ in parallel with 20 pF
|
|
Time Base Range
|
5 ns to 50 s/div
|
5 ns to 50 s/div
|
5 ns to 50 s/div
|
5 ns to 50 s/div
|
5 ns to 50 s/div
|
5 ns to 50 s/div
|
5 ns to 50 s/div
|
2.5 ns to 50 s/div
|
2.5 ns to 50 s/div
|
|
Time Base Accuracy
|
50 ppm
|
|
Horizontal Zoom
|
Horizontally expand or compress a live or stopped
waveform
|
|
I/O Interfaces
|
|
USB Ports
|
USB host port on front panel supports USB flash
drives
USB device port on back of instrument supports connection
to PC and all PictBridge-compatible printers
|
|
GPIB
|
Optional
|
|
Nonvolatile Storage
|
|
Reference Waveform Display
|
(2) 2.5K point reference waveforms
|
|
Waveform Storage w/o USB Flash Drive
|
(2) 2.5K point
|
(2) 2.5K point
|
(2) 2.5K point
|
(2) 2.5K point
|
(4) 2.5K point
|
(2) 2.5K point
|
(4) 2.5K point
|
(2) 2.5K point
|
(4) 2.5K point
|
|
Maximum USB Flash Drive Size
|
64 GB
|
|
Waveform Storage with USB Flash Drive
|
96 or more reference waveforms per 8 MB
|
|
Setups w/o USB Flash Drive
|
10 front-panel setups
|
|
Setups with USB Flash Drive
|
4000 or more front-panel setups per 8 MB
|
|
Screen Images with USB Flash Drive
|
128 or more screen images per 8 MB (the number
of images depends on file format selected)
|
|
Save All with USB Flash Drive
|
12 or more Save All operations per 8 MB
A single Save All operation creates 3 to 9 files (setup, image, plus
one file for each displayed waveform)
|
*2 Bandwidth is 20 MHz at 2 mV/div, all
models.
Acquisition Modes
Peak Detect - High-frequency
and random-glitch capture. Captures glitches as narrow as 12 ns (typical)
at all time base settings from 5 μs/div to 50 s/div.
Sample
- Sample data only.
Average - Waveform averaged,
selectable: 4, 16, 64, 128.
Single Sequence - Use the
Single Sequence button to capture a single triggered acquisition sequence.
Roll Mode - At acquisition time base settings of >100 ms/div.
Trigger System
Trigger Modes - Auto, Normal,
Single Sequence.
Trigger Types
Edge (rising/falling)
- Conventional level-driven trigger. Positive or negative slope
on any channel. Coupling selections: AC, DC, Noise Reject, HF Reject,
LF Reject.
Video - Trigger on all lines or individual
lines, odd/even or all fields from composite video, or broadcast standards
(NTSC, PAL, SECAM).
Pulse Width (or Glitch) - Trigger
on a pulse width less than, greater than, equal to, or not equal to,
a selectable time limit ranging from 33 ns to 10 s.
Trigger
Source
2-channel Models - CH1, CH2, Ext, Ext/5, AC
Line.
4-channel Models - CH1, CH2, CH3, CH4, Ext, Ext/5,
AC Line.
Trigger View
Displays trigger signal while
trigger view button is depressed.
Trigger Signal Frequency
Readout
Provides a frequency readout of the trigger source.
Cursors
Types - Amplitude, Time.
Measurements - ΔT, 1/ΔT, ΔV.
Automatic Waveform Measurements
Period, Frequency, +Width, –Width, Rise Time, Fall Time, Max,
Min, Peak-to-Peak, Mean, RMS, Cycle RMS.
Waveform Math
Operators - Add, Subtract, Multiply, FFT.
FFT - Windows: Hanning, Flat Top, Rectangular; 2048 sample points.
Sources -
2-channel models: CH1 – CH2, CH2 – CH1,
CH1 + CH2, CH1 × CH2.
4-channel models: CH1 – CH2, CH2 – CH1,
CH3 – CH4, CH4 – CH3, CH1 + CH2, CH3 + CH4, CH1 × CH2, CH3 × CH4.
Autoset Menu
|
Signal Type
|
Autoset Menu Choices
|
|
Single-button, automatic setup of all channels
for vertical, horizontal, and trigger systems, with undo Autoset.
|
|
Square Wave
|
Single Cycle, Multicycle, Rising or Falling Edge
|
|
Sine Wave
|
Single Cycle, Multicycle, FFT Spectrum
|
|
Video (NTSC, PAL, SECAM)
|
Field: All, Odd, or Even
Line: All or Selectable Line
Number
|
Autorange
Automatically adjust vertical
and/or horizontal oscilloscope settings when probe is moved from point
to point, or when the signal exhibits large changes.
Display
Characteristics
Display -
Color models: ¼ VGA
passive color LCD with color on black background with adjustable multilevel
contrast.
Monochrome models: ¼ VGA backlit passive LDC with
adjustable multilevel contrast and inverse video selectable from front
panel.
Interpolation - Sin(x)/x.
Display
Types - Dots, vectors.
Persistence - Off, 1 s,
2 s, 5 s, infinite.
Format - YT and XY.
Multiple-language
User Interface and Context-sensitive Help
Languages Available
- English, French, German, Italian, Japanese, Korean, Portuguese,
Russian*3, Simplified Chinese, Spanish, Traditional Chinese.
Environmental and Safety
Temperature -
Operating:
0 to +50 ºC.
Nonoperating: –40 to +71 ºC.
Humidity
-
Operating and Nonoperating: Up to 80% RH at or below +40 ºC.
Operating and Nonoperating: Up to 45% RH up to +50 ºC.
Altitude -
Operating and Nonoperating: Up to 3,000 m.
Electromagnetic Compatibility - Meets Directive
89/336/EEC, amended by 93/68/EEC, meets or exceed EN55011 Class A
Radiated and Conducted Emissions; FCC 47 CFR, Part 15, Subpart B,
Class A; Australian EMC Framework, demonstrated per Emission Standard
AS/NZS 2064; Russian GOST EMC regulations.
Safety - UL61010-1:2003, CSA22.2 No. 61010-1:2003, EN61010-1:2001, IEC61010-1:2001.
Physical Characteristics
|
Instrument
|
|
Dimensions
|
mm
|
in.
|
|
Width
|
326.3
|
12.85
|
|
Height
|
158.0
|
6.22
|
|
Depth
|
124.2
|
4.89
|
|
Weight
|
kg
|
lb.
|
|
Instrument Only
|
2.0
|
4.4
|
|
With accessories
|
2.2
|
4.9
|
|
Instrument Shipping
|
|
Package Dimensions
|
mm
|
in.
|
|
Width
|
476.2
|
18.75
|
|
Height
|
266.7
|
10.5
|
|
Depth
|
228.6
|
9.0
|
|
RM2000B Rackmount
|
mm
|
in.
|
|
Width
|
482.6
|
19.0
|
|
Height
|
177.8
|
7.0
|
|
Depth
|
108.0
|
4.25
|
*3 Requires Russian firmware, indicated
by "RUS" suffix.
Ordering Information
TDS1001B: 40 MHz,
2 Ch, 500 MS/s, Monochrome DSO.
TDS1002B: 60 MHz, 2
Ch, 1 GS/s, Monochrome DSO.
TDS1012B: 100 MHz, 2 Ch,
1 GS/s, Monochrome DSO.
TDS2002B: 60 MHz, 2 Ch, 1 GS/s,
Color DSO.
TDS2004B: 60 MHz, 4 Ch, 1 GS/s, Color DSO.
TDS2012B: 100 MHz, 2 Ch, 1 GS/s, Color DSO.
TDS2014B: 100 MHz, 4 Ch, 1 GS/s, Color DSO.
TDS2022B: 200 MHz, 2 Ch, 2 GS/s, Color DSO.
TDS2024B: 200 MHz,
4 Ch, 2 GS/s, Color DSO.
Standard Accessories
Passive Probes - 200 MHz (one per channel).
Power
Cord - (Please specify plug option).
NIM/NIST - Traceable Certificate of Calibration.
Documentation - User Manual (Please specify preferred language option).
OpenChoice PC Communications Software - Enables fast and easy
communication between a Windows PC and the TDS1000B and TDS2000B Series
using USB. Transfer and save settings, waveforms, measurements, and
screen images.
National Instruments SignalExpress Tektronix
Edition Interactive Measurement Software - Base Version - A fully
interactive measurement software environment optimized for the TDS1000B
and TDS2000B Series. Enables you to instantly acquire, generate, analyze,
compare, import, and save measurement data and signals using intuitive
drag-and-drop user interface that does not require any programming.
Standard TDS1000B and TDS2000B Series support for acquiring, controlling,
viewing, and exporting your live signal. A 30-day trial period of
the Professional Version provides additional signal processing, advance
analysis, mixed signal, sweeping, limit testing, and user-defined
step capabilities. Order SIGEXPTE for permanent Professional Version
capability.
Limited Lifetime Warranty*4 covering
labor and parts for defects in materials and workmanship for a minimum
of 10 years, excluding probes and accessories*5.
International Power Plugs
Opt. A0 - North America
power.
Opt. A1 - Universal EURO power.
Opt.
A2 - United Kingdom power.
Opt. A3 - Australia
power.
Opt. A5 - Switzerland power.
Opt.
A6 - Japan power.
Opt. A10 - China power.
Opt. A11 - India power.
Opt. A99 - No power
cord or AC adapter.
User Manual Options
Opt. L0
- English manual.
Opt. L1 - French manual.
Opt. L2 - Italian manual.
Opt. L3 - German
manual.
Opt. L4 - Spanish manual.
Opt. L5
- Japanese manual.
Opt. L6 - Portuguese manual.
Opt. L7 - Simple Chinese manual.
Opt. L8 - Standard Chinese manual.
Opt. L9 - Korean manual.
Opt. L10 - Russian manual.
Translated
front-panel overlays included with their respective user manuals.
Recommended Accessories
TEK-USB-488 - GPIB-to-USB
converter.
SIGEXPTE - National Instruments SignalExpress
Tektronix Edition Interactive Measurement Software - Professional
Version.
AC2100 - Soft Carrying Case for Instrument.
HCTEK4321 - Hard Plastic Carrying Case for Instrument
(requires AC2100).
RM2000B - Rackmount Kit.
071-1075-xx - Programmer Manual - English Only.
071-1828-xx - Service Manual - English Only.
TNGTDS01
- Operator Training Kit - Extensive instructions and step-by-step
lab exercises provide education about the operation of TDS1000B and
TDS2000B Series oscilloscopes. Kit includes self-paced CD-ROM-based
manual and signal source board.
174-4401-xx - USB host
to device cable, 3 feet long.
Recommended Probes
P2220 - 10x to 1x Switchable Passive Probe (200 MHz when 10x
is selected).
P6101B - 1x passive probe (15 MHz, 300 VRMS CAT II rating).
P6015A - 1000x high-voltage
passive probe (75 MHz).
P5100 - 100x high-voltage passive
probe (75 MHz).
P5200 - High-voltage active differential
probe (25 MHz).
P6021 - 15 A, 60 MHz AC current probe.
P6022 - 6 A, 120 MHz AC current probe.
A621
- 2000 A, 5 to 50 kHz AC current probe.
A622 - 100 A, 100 kHz AC/DC current probe/BNC.
TCP303/TCPA300
- 15 A, 15 MHz AC/DC current probe/amplifier.
TCP305/TCPA300
- 50 A, 50 MHz AC/DC current probe/amplifier.
TCP312/TCPA300
- 30 A, 100 MHz AC/DC current probe/amplifier.
TCP404XL/TCPA400
- 500 A, 2 MHz AC/DC current probe/amplifier.
Service
Options*5
Opt. C3 - Calibration Service
3 Years.
Opt. C5 - Calibration Service 5 Years.
Opt. D1 - Calibration Data Report.
Opt. D3
- Calibration Data Report 3 Years (with Opt. C3).
Opt.
D5 - Calibration Data Report 5 Years (with Opt. C5).
Opt. CA1 - Provides a single calibration event or coverage for
the designated calibration interval, whichever comes first.
*4 Lifetime is defined as five years after Tektronix discontinues
manufacturing the product, but the warranty length shall be at least
ten years from date of original purchase. Lifetime warranty is nontransferable,
proof of original purchase is required. Limitations apply. For terms
and conditions visit www.tektronix.com/lifetimewarranty.
*5 Probes and accessories are not covered by the oscilloscope
warranty and Service Offerings. Refer to the datasheet of each probe
and accessory model for its unique warranty and calibration terms.
Service Offerings (Available after purchase)
TDSxxxxB-CA1 - Provides a single calibration event or coverage
for the designated calibration interval, whichever comes first.
The Complete Measurement Solution
The AFG3000 Series
arbitrary function generator pairs with the TDS2000B and TDS1000B
Series digital storage oscilloscopes to deliver the two elements of
a complete measurement solution – stimulus and acquisition. This instrument
combines the capabilities of a function generator with the power of
an arbitrary waveform generator, offering the performance needed to
accurately verify, validate, and characterize designs with ease and
confidence at a price you can afford.
The Tektronix Customer
Service Advantage
You can trust Tektronix to offer unequalled
engineering expertise and a customer-centric approach to ensure the
optimal performance of your Tektronix products and maximize the lifetime
value of your Tektronix investment. With service from Tektronix you
get:
- Access to the source of product knowledge; unsurpassed
technical expertise
- Your challenges solved by front-line
technical experts, design engineering reinforcement, and online support
tools
- Comprehensive and thorough support provided worldwide,
including software and firmware updates, data reports, and adjustments
- Efficiency and convenience; no hassle service from initial service
call to turnaround and delivery
- Flexible repair and calibration
service with access to the best on-call technical troubleshooting
staff in the industry, with over 20 years of training per support
engineer
- Customer-centric approach dedicated to serving your
needs everyday with services designed to optimize your product performance,
increase productivity and ROI by delivering a fixed cost of ownership,
and efficient management of service
Get checked by Tektronix.
Visit www.tektronix.com/serviceandsupport.
|
|
Product(s) are manufactured in ISO registered facilities.
|
|
Product(s) complies with IEEE Standard 488.1-1987, RS-232-C,
and with Tektronix Standard Codes and Formats.
|
3GW-19558-2, 23-OCT-2009
|