DCSIMG
Tektronix » 產品摘要 » 產品 » 示波器 » 500Mhz 至 5Ghz 的示波器示波器 » TDS5000B系列


Click to Enlarge

產品資訊
簡介
特性/規格
訂購資訊
可列印的產品規格表 (9 MB)

購買資訊
請業務拜訪
安排展示

要求報價單

其他資訊
Find an Authorized Distributorwidth=10
TDS5000B width=10
Digital/Analog Integrationwidth=10
OpenChoice™ 解決方案width=10
On-line Probe Selector width=10

數位螢光示波器

TDS5034B • TDS5054B • TDS5104B

Characteristics

Vertical System

   TDS5034BTDS5054BTDS5104B
Input Channels4
Analog Bandwidth (-3 dB) 5 mV/div - 1 V/div350 MHz500 MHz1 GHz
Calculated Rise Time 5 mV/div (typical)1.15 ns800 ps300 ps
Hardware Bandwidth Limits150 MHz or 20 MHz
Input CouplingAC, DC, GND
Input Impedance, 1 MΩ±1%
Input Impedance, 50 Ω±1%±2.5%
Input Sensitivity, 1 MΩ1 mV/div to 10 V/div
Input Sensitivity, 50 Ω1 mV/div to 1 V/div
Vertical Resolution8-bits (>11-bits w/ averaging)
Max Input Voltage, 1 MΩ150 V CAT I, ≤ 400 V peak. Derate at 20 dB/decade to 9 VRMS above 200 kHz
Max Input Voltage, 50 Ω5 V RMS with peaks <±30 V

<100 mV/div <1 VRMS

≥100 mV/div <5 VRMS

DC Gain Accuracy1.5% with offset set to 0 V
Offset Range, 1 MΩ

1 mV/div - 99.5 mV/div ±1 V

100 mV/div - 1 V/div ±10 V

1.01 V/div - 10 V/div ±100 V

Offset Range, 50 Ω

1 mV/div - 99.5 mV/div ±1 V

100 mV/div -1 V/div ±10 V

1 mV/div - 50 mV/div ±0.5 V

50.5 mV/div - 99.5 mV/div ±0.25 V

100 mV/div - 500 mV/div ±5 V

505 mV/div - 1 V/div ±2.5 V

Channel-to-channel Isolation for Any Two Channels at Equal Vertical Scale≥100:1 at ≤100 MHz and ≥30:1 at >100 MHz up to the rated bandwidth

 

Timebase System

Timebase Range200 ps/div to 1000 s/div
Timebase Delay Time Range(s/div × 10) to 1000 s
Channel-to-channel Deskew Range±75 ns
Timebase Accuracy15 ppm
Delta Time Measurement Accuracy(0.06/sample rate + 15 ppm × |Reading|)RMS
Trigger Jitter (RMS)8 psRMS (typical)
Long Term Sample Rate and Delay Time Accuracy±15 ppm over any ≥1 ms interval

 

Acquisition System

   TDS5034BTDS5054B / TDS5104B
Real-time Sample Rates        
   1 Channel (max)5 GS/s
   2 Channels (max)2.5 GS/s
   3-4 Channels (max)1.25 GS/s
Equivalent Time Sample Rate (max)250 GS/s
Maximum Record Length per Channel with Standard Memory8M/4M/2M--16M/8M/4M
With Opt. 3M16M/8M/4MNA

 

Maximum Duration at Highest Real-time Resolution (1 ch)

   TDS5034BTDS5054B / TDS5104B
Time Resolution (single shot)200 ps (5 GS/s)
Max Duration with Standard Memory1.6 ms3.2 ms
Max Duration with Opt. 3M3.2 msNA

 

Acquisition Modes

FastAcq AcquisitionFastAcq optimizes the instrument for analysis of dynamic signals and capture of infrequent events. Maximum FastAcq waveform capture rate is 100,000 wfms/s.
SampleAcquire sampled values
Peak DetectCaptures narrow glitches (<1 ns) at all real-time sampling rates
AveragingFrom 2 to 10,000 waveforms included in average
EnvelopeFrom 2 to 2 × 109 waveforms included in min-max envelope
Hi-ResReal-time boxcar averaging reduces random noise and increases resolution
Waveform DatabaseAccumulates a waveform database that provides a three dimensional array of amplitude, time, and counts
FastFrame™ AcquisitionAcquisition memory divided into segments; maximum trigger rate >100,000 waveforms per second

 

Trigger System

Sensitivity
Internal DC Coupled0.35 div DC to 50 MHz increasing to 1 div at rated bandwidth
External (auxiliary input)400 mV from DC to 50 MHz increasing to 750 mV at 100 MHz
Main Trigger ModesAuto, Normal, and Single
Trigger SequencesMain, Delayed by time, Delayed by events. All sequences can include separate horizontal delay after the trigger event to position the acquisition window in time.
Standard Trigger TypesEdge, Glitch, Runt, Window, Width, Transition Time, Timeout, Pattern, Video, State, Setup/Hold
A Event and Delayed B Event Trigger Types    
   A EventAll above types
   Delayed B EventEdge
Communications-related Triggers (requires Option SM)Support for AMI, HDB3, BnZS, CMI, MLT3, and NRZ encoded communications signals. Select among isolated positive or negative one, zero pulse form or eye patterns as applicable to standard
Trigger Level Range
Any Channel±10 divisions from center of screen
External (auxiliary in)±8 V
LineFixed at 0 V
Trigger Coupling

DC, AC (attenuate <60 Hz), HF reject (attenuate >30 kHz)

LF reject (attenuates <80 kHz) Noise reject (reduce sensitivity)

Trigger Holdoff Range1.5 μs to 12 s maximum
Trigger Modes
EdgePositive or negative slope on any channel or front panel auxiliary input. Coupling includes DC, AC, noise reject, HF reject, and LF reject.
VideoTrigger on NTSC, PAL, SECAM, analog HDTV, and non-standard video formats
GlitchTrigger on or reject glitches of positive, negative or either polarity. Minimum glitch width is 1.0 ns with 200 ps resolution.
WidthTrigger on width of positive or negative pulse either within or out of selectable time limits ranging from 1 ns to 1 s with 200 ps resolution
RuntTrigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again. Event can be time or logic qualified (logic on 4 channel models only).
WindowTrigger on an event that enters or exits a window defined by two user-adjustable thresholds. Event can be time or logic qualified (logic on 4 channel models only).
TimeoutTrigger on an event which remains high, low or either, for a specified time period, selectable from 1 ns to 1 s with 200 ps resolution.
TransitionTrigger on pulse edge rates that are faster or slower than specified. Slope may be positive, negative or either
Setup/HoldTrigger on violations of both setup time and hold time between clock and data present on any two input channels
PatternTrigger when pattern goes false or stays true for specified period of time. Pattern (AND, OR, NAND, NOR) specified for four input channels defined as High, Low or Don't Care.
StateAny logical pattern of channels (1, 2, 3) clocked by edge on channel 4. Trigger on rising or falling clock edge
Comm (requires option SM)Support for AMI, HDB3, B3ZS, B6ZS, B8ZS, CMI, NRZ and MLT3 encoded communication signals. Select among isolated positive or negative one, zero pulse form or eye patterns as applicable to standard.
Trigger Delay by Time16 ns to 250 seconds
Trigger Delay by Events1 to 10,000,000 Events
Waveform Measurements
Automatic Measurements53 of which 8 can be displayed on screen at any one time
   Amplitude RelatedAmplitude, High, Low, Maximum, Minimum, Peak to Peak, Mean, Cycle Mean, RMS, Cycle RMS, Positive Overshoot, Negative Overshoot
   Time RelatedRise Time, Fall Time, Positive Width, Negative Width, Positive Duty Cycle, Negative Duty Cycle, Period, Frequency, Delay
   CombinationArea, Cycle Area, Phase, Burst Width
   Histogram RelatedWaveform count, Hits in box, Peak hits, Median, Maximum, Minimum, Peak to Peak, Mean (μ), Standard Deviation (σ), μ ± 1σ, μ ± 2σ, μ ± 3σ
   Communications RelatedExtinction Ratio (abs, %, dB), Eye Height, Eye Width, Eye Top, Eye Base, Crossing %, Jitter (Pk-Pk, RMS, 6σ), Noise (Pk-Pk, RMS), Signal/Noise Ratio, Cycle Distortion, Q-Factor
Measurement StatisticsMean, Min, Max, Standard Deviation, Population
Reference LevelsUser definable for each of the eight measurements
HistogramsVertical or horizontal with linear or log scaling
GatingIsolate the specific occurrence within an acquisition to take measurements on
CursorsHorizontal Bars, Vertical Bars, Waveform, and Screen
Waveform Processing/Math
ArithmeticAdd, subtract, multiply, and divide waveforms
Algebraic ExpressionsDefine extensive algebraic expressions including waveforms, scalars, user adjustable variables, and results of parametric measurements e.g. (Integral (Ch1-Mean(Ch1))*1.414*VAR1)
Math FunctionsAverage, Invert, Integrate, Differentiate, Square Root, Exponential, Log 10, Log e, Abs, Ceiling, Floor, Min, Max, Sin, Cos, Tan, ASin, ACos, ATan, Sinh, Cosh, Tanh
Frequency Domain FunctionsSpectral magnitude and phase, real and imaginary spectra
Vertical UnitsMagnitude: Linear, dB, dBm. Phase: degrees, radians, group delay
Window FunctionsRectangular, Hamming, Hanning, Kaiser-Bessel, Blackman-Harris, Gaussian, Flattop2, Tek Exponential
Limit TestingCompare live waveforms against a known “golden” reference waveform with user defined vertical and horizontal tolerances
Display Characteristics
Display Type10.4 in. Liquid crystal active-matrix color display
Touch ScreenStandard on TDS5054B and TDS5104B. Optional Touch Screen on TDS5034B
Display Resolution640 horizontal x 480 vertical pixels
Waveform StylesVectors, Dots, Intensified Samples, Variable Persistence, Infinite Persistence
Display FormatYT, XY, XYZ
Color PalettesIndividual color palettes for Record View and FastAcq/WfmDB modes include Normal, Green, Gray, Temperature, Spectral, and User Defined
Computer System and Peripherals
Operating SystemWindows 2000.
CPUIntel Celeron Processor, 2.0 GHz
PC System Memory512 MB
Internal Hard Disk Drive≥80 GB capacity
CD-RW DriveSide panel CD-RW drive, ≥24X read and write speed
MouseOptical wheel mouse, USB interface
OpenChoice Features
TekVISAApplication Programmers Interface (API) for Windows developers. Documentation includes descriptions and samples of programming test and measurement applications on the unit in Visual BASIC, C and C++.
TekVISA Control (TVC)Active controls to make access to TekVISA easy for integration into Microsoft Windows applications
VXI-11 ServerAn Application Programmers Interface (API) for LAN connectivity from non-Windows environments
Plug-and-play DriversProvides support to run National Instrument's LabVIEW and LabWindows on an external PC connected to a TDS5000B or on the oscilloscope itself. Instrument drivers are version specific and might not support the version of your software development tools.
IVI DriversProvides support for new and existing program environments utilizing the IVI instrumentation standard, such as LabVIEW, LabWindows/CVI, MATLAB, Visual BASIC, and C/C++. Instrument drivers are version specific and might not support the version of your software development tools.
Excel and Word ToolbarsProvides direct access to screen images, waveform data, and measurements on the oscilloscope from a toolbar in Excel and/or Word
Report GeneratorEnables the ability to design and create customized report templates that extract the oscilloscope's waveforms, settings, measurements, and other on-screen information with a click of the mouse
Input/Output Ports
Auxiliary InputFront panel BNC connector. Trigger level range is adjustable from +8 V to -8 V. The maximum input voltage is ±20 V (DC + peak AC) and input resistance is ≥1.5 kΩ.
Probe Compensator OutputFront panel pins. Amplitude 1 V ± 1% into a ≥10 kΩ load, frequency 1 kHz ±5%
Analog Signal OutputRear-panel BNC connector, provides a buffered version of the signal that is attached to the Channel 3 input (4 channel models only). Amplitude: 50 mV/div ±20% into a 1 MΩ load, 25 mV/div ±20% into a 50 Ω load. Bandwidth (typical): 100 MHz into a 50 Ω load.
Auxiliary Output LevelsRear-panel BNC connector, provides a TTL-compatible, negative polarity pulse when the oscilloscope triggers
External Reference InRear-panel BNC connector. 9.8 MHz to 10.2 MHz
Parallel PortIEEE 1284, DB-25 connector
Audio PortsMiniature phone jacks for stereo microphone input and stereo line output
USB PortFour USB 2.0 ports allows connection or disconnection of USB keyboard and/or mouse while oscilloscope power is on
Keyboard PortPS-2 compatible
Mouse PortPS-2 compatible
LAN PortRJ-45 connector, supports 10Base-T and 100Base-T
Serial PortDB-9 COM1 port
Video PortDB-15 female connector; connect a second monitor to use dual-monitor display mode. Supports basic requirements of PC99 specification and display resolutions up to 1,920 x 1,440
GPIB PortIEEE 488.2 standard, can be configured for talk/listen or controller mode
Oscilloscope VGA Video PortDB-15 female connector, connect to show the oscilloscope display on an external monitor or projector

 

Power Source

Power100 to 240 VRMS ±10%, 47 to 63 Hz; CAT II, or 115 VRMS ±10%, 360 to 440 Hz
Power Consumption<220 W

 

Physical Characteristics

Configuration Benchtop Rackmount Benchtop Rackmount
Dimensions mm in.
   Height36126711.2*1 10.5
   Width44748317.619
   Depth288231*2 11.359.1*2
Weightkg lbs.
   Net11.2313.4924.7529.75
   Shipping25.6356.5
Cooling    
   Cooling clearance76 mm required on left side3 inches required on left side

*1 Does not include accessory pouch.

*2 From rack mounting rear to back of instrument.

Environmental
Temperature    
   Operating+5 °C to +45 °C
   Nonoperating-20 °C to +60 °C without diskette in floppy drive
Humidity    
   Operating20% to 80% relative humidity with a maximum wet bulb temperature of +29 °C at or below +45 °C, noncondensing. Upper limit de-rates to 30% relative humidity at +45 °C.
   NonoperatingWithout diskette in floppy disk drive. 5% to 90% relative humidity with a maximum wet bulb temperature of +29 °C at or below +60 °C, noncondensing. Upper limit derates to 20% relative humidity at +60 °C.
Altitude    
   Operating10,000 ft. (3,048 m)
   Nonoperating40,000 ft. (12,190 m)
Random Vibration    
   Operating0.1 GRMS from 5 to 500 Hz, 10 minutes each axis, 3-axes, 30 minutes total
   Nonoperating2.0 GRMS from 5 to 500 Hz, 10 minutes each axis, 3-axes, 30 minutes total
Regulatory Certifications    
   Electromagnetic Compatibility89/336/EEC
   SafetyUL61010, CSA-22.2 No. 1010.1, EN61010-1, IEC61010-1

Ordering Information

TDS5034B

350 MHz, 5 GS/s, 4 channel digital phosphor oscilloscope.

TDS5054B

500 MHz, 5 GS/s, 4 channel digital phosphor oscilloscope

TDS5104B

1 GHz, 5 GS/s, 4 channel digital phosphor oscilloscope

Includes: (1) P5050 500 MHz, 10x passive probe per channel, Accessory Pouch (016–1935–00), Front Cover (200-4651-00), Mouse (119-6936-00), Quick Start User Manual, TDS5000B Product Software CD-ROM, TDS5000B Operating System Restoration CD-ROM, GPIB Programmer's Reference, Optional Applications Software CD-ROM, Getting Started with OpenChoice® book (020-2513-00), Performance Verification Procedure PDF file, Calibration Certificate Documenting NIST Traceability, Z540-1 Compliance, and ISO9001 Registration, Power Cord.Note: Please specify power plug and manual version when ordering.

Recommended Probes
P5050500 MHz, 10x passive probe
P62431.0 GHz active probe
P62451.5 GHz active probe
P6246400 MHz differential probe
P62471.0 GHz differential probe
P62481.7 GHz differential probe
P6250DC to 500 MHz, 42 V, Differential Probe (requires TCA-BNC adapter)
P6251DC to 1 GHz, 42 V, Differential Probe (requires TCA-BNC adapter)
Recommended Accessories
Service ManualOrder 071-1362-00
Transit CaseOrder 016-1937-00
Probe Calibration, Compensation, and Deskew AdapterOrder 067-0405-xx
Power Deskew FixtureOrder 067-1478-00
Mini KeyboardOrder 118-9402-00
USB Test FixtureOrder TDSUSBF
Ethernet Test FixtureOrder through Crescent Heart Software (www.c-h-s.com)
Instrument Options (Available on all models unless indicated otherwise)
Opt. 18Touch-screen interface for TDS5034B
Opt. 3MIncrease record length to 16M samples max (1ch.) for TDS5034B
Opt. 1KOscilloscope cart
Opt. 1RRackmount kit
Opt. SM        Communication mask testing
Opt. VNMCAN bus decode requires ATM1 trigger module
Opt. PS1Power Bundle that includes TCP202 DC Coupled Current Probe, P5205 High Voltage Differential Probe, TDSPWR3 Power Measurement Software, and Power Deskew Fixture
Opt. CP2*1 TDSCPM2 - ANSI/ITU telecom pulse compliance testing software
Opt. ET3TDSET3 - Ethernet compliance test software
Opt. J2*2 TDSDDM2 - Disk drive measurements software
Opt. JA3TDSJIT3 v2.0 Advanced - Jitter and timing analysis software
Opt. JE3TDSJIT3 v2.0 Essentials - Jitter and timing analysis software
Opt. PW3TDSPWR3 - Power measurements software
Opt. USB     USB 2.0 Compliance test software only

*1  Requires option SM.

*2  Not available on TDS5034B.

 

Power Plug Options
Opt. A0North America
Opt. A1Universal Euro
Opt. A2United Kingdom
Opt. A3Australia
Opt. A4240V North America
Opt. A5Switzerland
Opt. A6Japan
Opt. A10China
Opt. A99    No power cord or AC adapter
Manual Options
Opt. L0English Manual
Opt. L1French Manual
Opt. L3German Manual
Opt. L5Japanese Manual
Opt. L7Simple Chinese Manual
Opt. L8Traditional Chinese Manual
Opt. L9Korean Manual
Opt. L10    Russian Manual
Service Options
Opt. C3Calibration Service 3 Years
Opt. C5Calibration Service 5 Years
Opt. D1Calibration Data Report
Opt. D3Calibration Data Report 3 Years (with Option C3)
Opt. D5Calibration Data Report 5 Years (with Option C5)
Opt. R3Repair Service 3 Years (including warranty)
Opt. R5       Repair Service 5 Years (including warranty)
Instrument Upgrades

Upgrades equivalent to original options can be ordered to extend instrument performance after initial purchase. Users can install upgrades without opening the instrument case or requiring on-site service (except for touch-screen upgrade for TDS5034B). To upgrade, order a TDS5BUP with one or more of the following options: 18, 1K, M03, 1R, SM, CP2, ET3, J2, JE3, JA3, PW3, USB, VNM. Factory installation of selected options is available by ordering option IF on your TDS5BUP upgrade order.




ISO9001 Product(s) are manufactured in ISO registered facilities.

55W-14869-13

(網站 ID: 13456)

back to top
產品資訊
簡介
特性/規格
訂購資訊
可列印的產品規格表 (9 MB)

購買資訊
請業務拜訪
安排展示

要求報價單

其他資訊
Find an Authorized Distributorwidth=10
TDS5000B width=10
Digital/Analog Integrationwidth=10
OpenChoice™ 解決方案width=10
On-line Probe Selector width=10

瀏覽 產品摘要

產品摘要 > 產品 > 示波器 > 500Mhz 至 5Ghz 的示波器示波器 > TDS5000B系列

產品摘要 > 產品 > 示波器 > 500Mhz 和以上的示波器示波器 > TDS5000B系列

產品摘要 > 產品 > 示波器 > 示波器一般資訊

產品摘要 > 產品 > 服務

產品摘要 > 產品 > 示波器 > DPO/DPX Architecture



Tektronix 文件需要最新版本的 PDF Adobe Acrobat Reader.