A621 • A622

Features & Benefits

A621
  • AC - 5 Hz to 50 kHz
  • 100 mA to 2000 A peak
  • For DMM's and Oscilloscopes
  • Clamp On
A622
  • AC/DC - 100 kHz
  • 50 mA to 100 A peak
  • For DMM's and Oscilloscopes

Applications

  • Motor Drives
  • Inverters
  • Power Supplies
  • Avionics

The A600 Series current probes high-value current probes are specifically designed to support measurements you make with your DMM, TekMeter® or oscilloscope*1.

A621 2000 Amp AC Current Probe/BNC

This industrial style clamp-on probe has a BNC connector and may be used with a shrouded banana plug adapter*1 so it can be used on digital multimeters, TekMeter, and scopes. The A621 can measure AC currents from 100 mA to 2000 A peak over a frequency range of 5 Hz to 50 kHz. It provides a 1 mV, 10 mV, or 100 mV output for each Amp measured.


A622

A622 100 Amp AC/DC Current Probe/BNC

This "long nose" style clamp-on probe uses a Hall Effect current sensor to provide a voltage output to oscilloscopes. It has a BNC connector and may be used with a shrouded banana plug adapter*1 so it can also be used on digital multimeters, TekMeter, and scopes. The A622 can measure AC/DC currents from 50 mA to 100 A peak over a frequency range of DC to 100 kHz. It provides 10 mV or 100 mV output for each Amp measured.

Probe Compatibility Chart

Part #

Description

DMM100*1

DMM200*1

DMM910*1

THS700*1

TX3/TX1*1

A621

AC Current Probe, 2000 A

Yes

Yes

Yes

Yes

yes

A622

AC/DC Current Probe, 100 A

Yes

Yes

Yes

Yes

yes

*1 For instruments with banana jack inputs, Tektronix part number 012-1450-00 Female BNC to banana lead adapter is required.

Typical Characteristics

   

A621

A622

Frequency Range

5 Hz to 50 kHz

DC to 100 kHz

Max. Input Current

2000 A peak

100 A peak

Output

1 mV / A 10 mV / A 100 mV / A

10 mV / A 100 mV / A

Max. Conductor Diameter

54 mm (2.13 in.)

11.8 mm (0.46 in.)

Termination

BNC *1

BNC *1

Max. Bare Wire Voltage

600 V (CATIII)

600 V (CATIII)

Safety

UL3111-2-032

CSA1010.2.032

EN61010-2-032

IEC61010-2-032

UL3111-2-032

CSA1010.2.032

EN61010-2-032

IEC61010-2-032

*1 For instruments with banana jack inputs, Tektronix part number 012-1450-00 Female BNC to banana lead adapter is required.

Ordering Information

A621

2000 A AC Current Probe/BNC.

A622

100 A AC/DC Current Probe/BNC.

Service

Opt. R3 - Repair Service 3 Years

Opt. R5 - Repair Service 5 Years

Recommended Accessories

A621, A622

Adapter, lead; discrete - MLD, 2, 18 AWG, dual insul, BNC, female X 4 mm dual insul; banana jack X dual insul plug, shield banana. Order 012-1450-xx.




CE Mark
ISO9001 Product(s) are manufactured in ISO registered facilities.

60W-15081-0c, 14-JUN-2005

(WebID: 13510)

back to top
Product Information
Introduction
Characteristics/Specs
Ordering Information
Printable Data Sheet (1 MB)

Purchasing Information
Check List Price
Request Sales Contact
Request a Demo

Request a Quote

Additional Information
Buy Onlinewidth=10
On-line Probe Selectorwidth=10

Navigate Data Sheets

Data Sheets > Products > Accessories > Oscilloscope Accessories > Oscilloscope Probes > Current Probes



Tektronix documents require the latest version of PDF Adobe Acrobat Reader.