Features
& Benefits
P6135A
- Attenuation Adjustable to 10X
- 10,000:
1 CMRR on 11A33 Differential Comparator; 20,000: 1 on 7A13 Differential Amplifier
- ±500 V Maximum
Common Mode Voltage
- Matched Pair
Applications
- Power
Supplies
- Disk Drives
- Electronic Ballast
- Intelligent
Motion
- Adjustable Speed Drives
P6135A Differential
Probe Pair
The P6135A differential probe pair is very carefully matched
to minimize differences in impedance and signal delay.
With differential
amplifiers the P6135A provides CMRR ratios up to 20,000:1. Since a single
10X probe with accuracy of 1% or less gives a scope-to-probe CMRR of no better
than 50:1, the P6135A is essential to obtain accurate results from your differential
amplifier. Three pairs of carefully matched, precision-engineered hybrid tips
enable the P6135A to be specifically matched with all Tektronix 11000, 7000
and 5000 Series differential amplifiers and comparators. It also provides
excellent performance when used with plug-in amplifiers or oscilloscopes having
input impedances of 1 MΩ/13-15 pF, 1 MΩ/18-22 pF and 1 MΩ/45-49 pF.
Characteristics
CMRR
-
On 11A33: 10,000:1 from DC to 1 kHz, derating to 100:1 at 20 MHz.
On
7000 Series: 20,000:1 from DC to 1 kHz derating to 100:1 at 20 MHz.
Attenuation
- Adjustable to 10X.
Input Resistance - 1 MΩ.
Input
Capacitance - 10.5 pF on instrument with 15 pF input capacitance; 11.0 pF
when used with instrument that has 20 pF input capacitance; 13.7 pF when used
with instrument that has 47 pF input capacitance.
Maximum Useful
Bandwidth -
On 11A33: DC to 150 MHz.
On 7A13: DC >90 MHz.
Typical
Probe Rise Time -
On 11A33: <2.33 ns.
On 7A13: <3.89 ns.
Maximum
Common Mode Voltage - 500 V (DC + pk AC) from DC to 1.3 MHz, derated to
50 V (DC + pk AC) at 100 MHz.
Safety - UL 1244.
Ordering
Information
P6135A
Pair of 10X, 150 MHz Differential Probes.
Includes: Adjustment
tool (003-1433-00); two retractable hook tips (013-0107-07); 6 in. dual-ring
ground lead (196-3295-00); accessory pouch (016-0708-00); two 6 in. ground
leads (196-3113-02); two 6 in. ground leads with alligator clips (196-3305-00);
two SMT KlipChip™ Adapters (206-0364-00); two low inductance GND collars (343-1003-01);
two probe tip holders (352-0670-00); 2 in. ground leads (195-4240-00); cable
marker rings; instruction manual (070-7675-01).
Recommended Accessories
See 3.5 mm Probe Accessories probe system.
P6135A not available in Europe.
|
|
Product(s) are manufactured in ISO registered facilities.
|
CE Marking Not Applicable.
|
60W-15112-0a, 01-DEC-2002
|