Analog/Mixed Sources Home Pagewidth=10

ArbExpress® 2.1 Waveform Tool for Tektronix AWG/AFG

AXW100

Features And Benefits

  • Comprehensive Library of Standard Functions for Quick Waveform Creation
  • Powerful Equation Editor for Mathematical Definition of Waveforms
  • Point Draw Tool for Entry of Waveform through a Numerical Table
  • Seamless Import of Oscilloscope Data with Optional Resampling of Waveform
  • Easy Transfer of Waveform Files to Connected ARB Directly from ArbExpress, or MATLAB
  • Validation of Waveform Parameters Specific to the Selected Instrument
  • Math Operations on Waveforms (Add, Subtract, Multiply, Divide)
  • Digital Marker Output Editor Allows for Easy Creation and Editing of Marker Pulses
  • Multiwaveform Overlay for Convenient Comparisons and Editing
  • Microsoft .NET-based Application

Applications

  • Configuration of ARBs in Characterization, Functional Test, Design, and Validation
  • Creation and Editing of Standard and Arbitrary Waveforms
  • Replication of Real-world Signals Recorded with DSO
  • Simulation of Sensor Outputs
  • Stimulation and Driving of Actuators
  • Phase Comparator Test with Controlled Phase Difference Signals
  • Frequency Response Test with Swept Signals
  • SFDR/IM Test with Multitone Signals

Efficient and Effortless Waveform Creation for Tektronix AWG and AFG

Designers frequently need to ensure their designs operate under real-world conditions. ARBs are ideally suited to generate any signal. ArbExpress enables engineers to quickly and conveniently create the desired waveforms and send them to Tektronix AFG/AWG arbitrary waveform and function generators.

Comprehensive Library of Waveforms and Flexible Editing Tools

ArbExpress’ large waveform library includes various standard and advanced functions that users can easily adapt to fit their needs. Individual signals can be combined with waveform math functions such as add or multiply, for example, for the addition of noise. Freehand, point drawing, and easy edit tools are available to shift or rotate waveform segments, or to augment signals with anomalies.

Link MATLAB Directly to ARB

All commands to open and close a connection to the ARB, transfer waveforms, remote control, and query the ARB can be conveniently included in a MATLAB program. Create waveforms directly in MATLAB, connect to the ARB, transfer waveform data, and control the instrument directly from the MATLAB command line.

Grab from Oscilloscope and Go!!

If sensor signals are difficult to access, but can be acquired with an oscilloscope once, they can be downloaded into an ARB and replicated indefinitely with ease. ArbExpress seamlessly imports acquisition data from Tektronix DSOs or from other scopes through .CSV files. If the sampling rates of the oscilloscope and ARB do not match, ArbExpress can resample the signal using linear or sinc algorithms.

Characteristics

User Interface - Windows 98 SE/ME/NT/2000/XP Professional.

Displays - Waveform and Marker Data.

Waveform Translation

Oscilloscope -

Import waveforms directly from TDS1000, TDS2000, TDS3000, TDS5000, TDS6000, TDS7000, or CSA7000 Series oscilloscopes.

Translation of oscilloscope .WFM waveform formats to AWG/AFG formats.

Resampling of signals with linear or sinc interpolation.

AWG - Tektronix AWG400, AWG500, AWG600, AWG700, and AWG2000 Series.

AFG - Tektronix AFG300, and AFG3000 Series.

MATHCAD - ASCII.

MATLAB - *.CSV, ASCII.

Others - *.CSV, ASCII.

Standard Waveforms

Basic Waveforms - Sine, Square, Triangle, DC, Pulse, Noise (Gaussian White, Pink), Exponential rise, and Exponential decay.

Advance Waveforms - Sinc, Sweep (linear), Multitone, and Lorentz.

Users can control all parameters of the waveform being created.

Parameters - Amplitude, Frequency, Phase, Cycles.

Extended Functions -

Supports preview before committing to changes.

Supports multiple waveform display.

Waveform Creation Palette

Manual Draw - Freehand, Vertical draw, Horizontal draw.

Point Draw - Enter waveform data as position and amplitude coordinates; linear, smooth, or staircase interpolation between points.

Edit Functions - Copy, Paste (Prepend, Append), Replace between cursors, Move Horizontally or Vertically, Rotate Horizontally or Vertically, Copy as Bitmap, Copy to System Clip Board, Zoom In, Zoom Out, Horizontal Zoom, Fit to Window, Cut, Undo, Redo, Invert, and Mirror.

Markers

Edit Markers - Modify between cursors, User-defined Patterns in Hex or Binary, Set High, Set Low, 0/1 Patterns, Random Patterns, Clear Patterns, and Freehand editing.

Equation Building

Math Operators - Add, Subtract, Multiply, Divide.

Math Functions - Linear, Absolute, Log, Square, Exponential, Integration, Differentiation, Normalize.

Supports Preview.

Equation Waveform Library - Comprehensive library of sample equations.

Waveform Math

Math Operators - Add, Subtract, Multiply, and Divide on Basic Waveforms, Scalar, and Clipboard.

Optionally Normalize Waveforms.

Waveform Transfer

Supports both NI VISA and TekVISA™ - GPIB (TekVISA), USB, (TekVISA), LAN (Raw Socket). Transfer waveform files to the ARB directly from MATLAB command line.

Instrument Control

Models - AFG3xx (GPIB), AFG3xxx (GPIB, USB, LAN), AWG20xx (GPIB), AWG4xx, AWG5xx, AWG6xx, AWG7xx (GPIB, LAN).

Controls -  

Analog: Run, Stop, Frequency, Amplitude, Offset, Phase, Filter, Clock, and Channel Output On/Off.

Digital Markers: Amplitude.

MATLAB - Instrument control directly from MATLAB command line.

System Requirements

OS Supported

Minimum requirements

Windows XP Professional Service Pack 1 or

Windows 2000 or

Windows ME or

Windows 98 SE

Windows NT Service Pack 6a

Pentium III at 800 MHz, or higher

256 MB RAM

300 MB free disk space

Microsoft Internet Explorer 5.01, or higher

.NET Framework 1.1 redistributable

800×600 display resolution

 

AWG/AFG

Oscilloscope

The following table lists conditions under which ArbExpress uses TekVISA™ version 2.03, build 97, or above:

LAN

AWG400, AWG500, AWG600, and AWG700 Series instruments are supported through raw sockets. (TekVISA may not be required*1).

AFG3000 Series instruments are supported through VXI 11 server

TekVISA required

GPIB

TekVISA required

TekVISA required

USB

TekVISA required*2

TekVISA required

RS232

Not supported

TekVISA required

*1 AFG3xx and AWG2xxx Series instruments do not support LAN.

*2 Only AFG3xxx supports USB.

Ordering Information

AXW100 ArbExpress

Available only as a free download from www.tektronix.com/axw.




76W-17871-3, 11-NOV-2005

(WebID: 13566)

back to top
Product Information
Introduction
Characteristics/Specs
Ordering Information
Printable Data Sheet (203 KB)

Purchasing Information
Request Sales Contact
Request a Demo

Request a Quote

Additional Information
Analog/Mixed Sources Home Pagewidth=10

Navigate Data Sheets

Data Sheets > Products > Signal Generators > Arbitrary Waveform / Function Generator > Other Arbitrary Waveform Generators

Data Sheets > Products > Accessories > Signal Sources Accessories

Data Sheets > Products > Signal Generators > Signal Sources Accessories

Data Sheets > Products > Signal Generators > Arbitrary Waveform / Function Generator > AFG300 Series (discontinued)

Data Sheets > Products > Signal Generators > Arbitrary Waveform / Function Generator > AWG400 Series

Data Sheets > Products > Signal Generators > Arbitrary Waveform / Function Generator > AWG500 Series

Data Sheets > Products > Signal Generators > Arbitrary Waveform / Function Generator > AWG600 Series

Data Sheets > Products > Signal Generators > Arbitrary Waveform / Function Generator > AFG3000 Series

Data Sheets > Products > Signal Generators > Arbitrary Waveform / Function Generator > AWG2000 Series

Data Sheets > Products > Signal Generators > Arbitrary Waveform / Function Generator > AWG700 Series



Tektronix documents require the latest version of PDF Adobe Acrobat Reader.