Features And Benefits
- Comprehensive Library of Standard
Functions for Quick Waveform Creation
- Powerful Equation Editor
for Mathematical Definition of Waveforms
- Point Draw Tool
for Entry of Waveform through a Numerical Table
- Seamless
Import of Oscilloscope Data with Optional Resampling of Waveform
- Easy Transfer of Waveform Files to Connected ARB Directly from
ArbExpress, or MATLAB
- Validation of Waveform Parameters Specific
to the Selected Instrument
- Math Operations on Waveforms (Add,
Subtract, Multiply, Divide)
- Digital Marker Output Editor
Allows for Easy Creation and Editing of Marker Pulses
- Multiwaveform
Overlay for Convenient Comparisons and Editing
- Microsoft
.NET-based Application
Applications
- Configuration of ARBs in
Characterization, Functional Test, Design, and Validation
- Creation and Editing of Standard and Arbitrary Waveforms
- Replication of Real-world Signals Recorded with DSO
- Simulation
of Sensor Outputs
- Stimulation and Driving of Actuators
- Phase Comparator Test with Controlled Phase Difference Signals
- Frequency Response Test with Swept Signals
- SFDR/IM
Test with Multitone Signals
Efficient
and Effortless Waveform Creation for Tektronix AWG and AFG
Designers frequently need to ensure their designs operate under real-world
conditions. ARBs are ideally suited to generate any signal. ArbExpress
enables engineers to quickly and conveniently create the desired waveforms
and send them to Tektronix AFG/AWG arbitrary waveform and function
generators.
Comprehensive Library of Waveforms and Flexible
Editing Tools
ArbExpress’ large waveform library includes
various standard and advanced functions that users can easily adapt
to fit their needs. Individual signals can be combined with waveform
math functions such as add or multiply, for example, for the addition
of noise. Freehand, point drawing, and easy edit tools are available
to shift or rotate waveform segments, or to augment signals with anomalies.
Link MATLAB Directly to ARB
All commands to open and
close a connection to the ARB, transfer waveforms, remote control,
and query the ARB can be conveniently included in a MATLAB program.
Create waveforms directly in MATLAB, connect to the ARB, transfer
waveform data, and control the instrument directly from the MATLAB
command line.
Grab from Oscilloscope and Go!!
If sensor
signals are difficult to access, but can be acquired with an oscilloscope
once, they can be downloaded into an ARB and replicated indefinitely
with ease. ArbExpress seamlessly imports acquisition data from Tektronix
DSOs or from other scopes through .CSV files. If the sampling rates
of the oscilloscope and ARB do not match, ArbExpress can resample
the signal using linear or sinc algorithms.
Characteristics
User Interface - Windows
98 SE/ME/NT/2000/XP Professional.
Displays - Waveform
and Marker Data.
Waveform Translation
Oscilloscope
-
Import waveforms directly from TDS1000, TDS2000, TDS3000,
TDS5000, TDS6000, TDS7000, or CSA7000 Series oscilloscopes.
Translation of oscilloscope .WFM waveform formats to AWG/AFG formats.
Resampling of signals with linear or sinc interpolation.
AWG - Tektronix AWG400, AWG500, AWG600, AWG700, and AWG2000
Series.
AFG - Tektronix AFG300, and AFG3000 Series.
MATHCAD - ASCII.
MATLAB - *.CSV, ASCII.
Others - *.CSV, ASCII.
Standard Waveforms
Basic Waveforms - Sine, Square, Triangle, DC, Pulse,
Noise (Gaussian White, Pink), Exponential rise, and Exponential decay.
Advance Waveforms - Sinc, Sweep (linear), Multitone,
and Lorentz.
Users can control all parameters of the waveform being
created.
Parameters - Amplitude, Frequency, Phase,
Cycles.
Extended Functions -
Supports preview before
committing to changes.
Supports multiple waveform display.
Waveform Creation Palette
Manual Draw - Freehand, Vertical draw, Horizontal draw.
Point Draw - Enter waveform data as position and amplitude coordinates; linear,
smooth, or staircase interpolation between points.
Edit
Functions - Copy, Paste (Prepend, Append), Replace between cursors,
Move Horizontally or Vertically, Rotate Horizontally or Vertically,
Copy as Bitmap, Copy to System Clip Board, Zoom In, Zoom Out, Horizontal
Zoom, Fit to Window, Cut, Undo, Redo, Invert, and Mirror.
Markers
Edit Markers - Modify between cursors, User-defined
Patterns in Hex or Binary, Set High, Set Low, 0/1 Patterns, Random
Patterns, Clear Patterns, and Freehand editing.
Equation Building
Math Operators - Add, Subtract, Multiply, Divide.
Math Functions - Linear, Absolute, Log, Square, Exponential,
Integration, Differentiation, Normalize.
Supports Preview.
Equation Waveform Library - Comprehensive library of
sample equations.
Waveform Math
Math Operators
- Add, Subtract, Multiply, and Divide on Basic Waveforms, Scalar,
and Clipboard.
Optionally Normalize Waveforms.
Waveform
Transfer
Supports both NI VISA and TekVISA™ - GPIB
(TekVISA), USB, (TekVISA), LAN (Raw Socket). Transfer waveform files
to the ARB directly from MATLAB command line.
Instrument Control
Models - AFG3xx (GPIB), AFG3xxx (GPIB, USB, LAN), AWG20xx
(GPIB), AWG4xx, AWG5xx, AWG6xx, AWG7xx (GPIB, LAN).
Controls
-
Analog: Run, Stop, Frequency, Amplitude, Offset, Phase,
Filter, Clock, and Channel Output On/Off.
Digital Markers:
Amplitude.
MATLAB - Instrument control directly
from MATLAB command line.
System Requirements
|
OS Supported
|
Minimum requirements
|
|
Windows XP Professional Service Pack 1 or
Windows 2000
or
Windows ME or
Windows 98 SE
Windows NT Service
Pack 6a
|
Pentium III at 800 MHz, or higher
256 MB RAM
300 MB free disk space
Microsoft Internet Explorer 5.01, or
higher
.NET Framework 1.1 redistributable
800×600 display
resolution
|
|
|
AWG/AFG
|
Oscilloscope
|
|
The following table lists conditions under
which ArbExpress uses TekVISA™ version 2.03, build 97, or above:
|
|
LAN
|
AWG400, AWG500, AWG600, and AWG700 Series instruments are
supported through raw sockets. (TekVISA may not be required*1).
AFG3000 Series instruments are supported through VXI 11
server
|
TekVISA required
|
|
GPIB
|
TekVISA required
|
TekVISA required
|
|
USB
|
TekVISA required*2
|
TekVISA required
|
|
RS232
|
Not supported
|
TekVISA required
|
*1 AFG3xx and AWG2xxx Series instruments
do not support LAN.
*2 Only AFG3xxx supports USB.