DCSIMG
Tektronix » Data Sheets » Products » Oscilloscopes » Oscilloscopes 5GHz and above » DSA8200


Click to Enlarge

Product Information
Introduction
Characteristics/Specs
Ordering Information
Printable Data Sheet (323 KB)

Purchasing Information
Request Sales Contact
Request a Demo

Request a Quote

Additional Information
DSA8200 Homewidth=10
Jitter and Timing Analysiswidth=10

PatternSync Trigger Module for the DSA8200 Series

80A06 PatternSync Trigger Module

Features & Benefits

  • Enables 80SJNB – The Advanced Jitter, Noise, and BER Analysis Software
  • Provides Trigger on Repetitive Patterns from 2 to 223 Bits Long
  • Provides Buffered Clock Output for Input to a Phase Reference Module or other Devices
  • Accepts Clock from Clock Recovery Circuits (CR) in the 80A05 and 80A07 Electrical Clock Recovery Modules, and in the Optical Modules
  • Optional SlotSaver Adapter Provides Power and Control of the PatternSync Trigger Modules, External to the Mainframe, Saving Space for Additional Channels

Applications

  • When Used in Combination with 80SJNB: Characterizing Jitter, Noise, and BER Performance of High-speed Serial Designs from 1 Gb/s to 60 Gb/s Data Rates
  • Design Validation and Testing of Next-generation High-speed Serial Data Computer and Communications Components and Systems
  • When Used in Combination with 80SJNB: Jitter, Noise, and BER Analysis of Multi-gigabit Standards such as Fibre Channel, OIF CEI, XFP, UXPi, SATA, PCI, Physical Layer, XAUI, Gigabit Ethernet, Rapid I/O, InfiniBand, and Other Electrical or Optical Circuits
  • Enables Capture of Bits in a Repetitive Pattern for Bit Analysis When Only a Clock is Available for Triggering
  • Enables FrameScan™ of Repetitive Patterns When Only a Clock Signal is Available for Triggering

*1 Also compatible with TDS/CSA8200, TDS/CSA8000B, and TDS/CSA8000 sampling oscilloscopes.

PatternSync Trigger Module

80A06 PatternSync Trigger module is required for the DSA8200 Series when using 80SJNB advanced Jitter, Noise, and BER Analysis software package. When this module is used with the 82A04 Phase Reference module, the jitter floor is ≤200 fsRMS.

The PatternSync Trigger Module is programmable to pattern lengths of up to 223 bits and accepts a user-supplied clock signal from 150 MHz to 12.75 GHz. The DSA8200 UI/PI for the 80A06 module offers pattern lengths from 2 to 223 bits and programs the module to within it's hardware range (a prescaler followed by a counter with minimum count of 30) for the least-common-multiple count.

Characteristics

Acquisition Modes - Standard, triggered phase reference, and FrameScan™

Compatible Mainframes - DSA8200, TDS/CSA8200, TDS/CSA8000B, and TDS/CSA8000

Mainframe Resources Required - One small (electrical) module slot, or TRIGGER PROBE POWER connector on the front panel of the oscilloscope (with available SlotSaver cable)

General Specifications

Input/Output Connectors - Precision 18 GHz SMA female connector

Input and Output Impedance - 50 Ω

Absolute Maximum Input Voltage - 2.0 Vpk-pk

Maximum DC Offset - ±5.0 VDC

Input Electrical Return Loss -

>15 dB (50 MHz to 10 GHz)

>10 dB (10 GHz to 20 GHz)

Input/Output Coupling -

CLOCK IN: AC

CLOCK OUT: AC

TRIGGER OUT: DC

Supported Clock Rates -

Minimum: 150 MHz

Maximum: 12.5 GHz, 12.75 GHz (typical)

Prescaler Ratios -

Input clock (as selected in the UI/PI)

150 MHz to 3.5 GHz: 4

3.5 GHz to 7 GHz: 8

7 GHz to 12.75 GHz: 16

Programmable Pattern Length -

Minimum: 2

Maximum: 223 (8,388,608)

Front-panel Output Amplitudes -

CLOCK OUT output (50 Ω AC coupled)

150 MHz to 8.0 GHz: 500 mVpk-pk (typical)

8.0 GHz to 12.75 GHz: 250 mVpk-pk (typical)

TRIGGER OUT output (50 Ω DC coupled, ground referenced)

Output High Level: 0 V

Output Low Level: -550 mV (typical)

Front-panel Output Rise and Fall Times -

CLOCK OUT: <60 ps (faster for fast input slew rate)

TRIGGER OUT: <60 ps (faster for fast input slew rate)

System Jitter -

DSA8200, TDS/CSA8200, and TDS/CSA8000B with 80A06: <1.3 psRMS, 850 fs RMS (typical)

TDS/CSA8000 with 80A06: <1.6 psRMS, 1.0 psRMS (typical)

DSA8200 and TDS/CSA8200 with 80A06 and 82A04: ≤200 fsRMS (determined by the 82A04, see 82A04 data sheet for more details).

Minimum Input Sensitivity - 200 mVpk-pk

Environmental and Mechanical

Dimensions

mm

in.

Height

25 

1.0

Width

79

3.1

Depth

135

5.3

Weight

kg

lb.

Net

0.4

0.6

Environmental Conditions - Refer to the host instrument specification.

Electromagnetic - Refer to the host instrument specification.

Ordering Information

80A06

PatternSync Trigger Module

Includes: User manual, 2 each 12 in. SMA cables (174-1364-xx).

Service Options

Opt. D1 - Calibration data reports.

Opt. R3. - Extend repair warranty to three years.

Accessories

Sampling Module Extender Cable (2 meter length) - Order 80N01.

SlotSaver Adapter Extender Cable - Brings power and control to the 80A06 when operated externally from the DSA mainframe, saving slot space (compatible with 80A06 and 80A02). Order 174-5230-xx.




CE Mark
ISO9001 Product(s) are manufactured in ISO registered facilities.

GPIB Logo Product(s) complies with IEEE Standard 488.1-1987, RS-232-C, and with Tektronix Standard Codes and Formats.

85W-18890-3, 29-JAN-2007

(WebID: 13583)

back to top
Product Information
Introduction
Characteristics/Specs
Ordering Information
Printable Data Sheet (323 KB)

Purchasing Information
Request Sales Contact
Request a Demo

Request a Quote

Additional Information
DSA8200 Homewidth=10
Jitter and Timing Analysiswidth=10

Navigate Data Sheets

Data Sheets > Products > Oscilloscopes > Oscilloscopes 5GHz and above > DSA8200

Data Sheets > Products > Oscilloscopes > Oscilloscopes 5GHz and above > Discontinued Oscilloscopes > TDS8000 Series (discontinued)

Data Sheets > Products > Oscilloscopes > Oscilloscopes 5GHz and above > Discontinued Oscilloscopes > TDS8000B Series (discontinued)

Data Sheets > Products > Oscilloscopes > Oscilloscopes 5GHz and above > Discontinued Oscilloscopes > CSA8000 Series (discontinued)

Data Sheets > Products > Oscilloscopes > Oscilloscopes 5GHz and above > Discontinued Oscilloscopes > CSA8000B Series (discontinued)

Data Sheets > Products > Oscilloscopes > Oscilloscopes 5GHz and above > Discontinued Oscilloscopes > CSA8200 (discontinued)

Data Sheets > Products > Oscilloscopes > Oscilloscopes 5GHz and above > Discontinued Oscilloscopes > TDS8200 (discontinued)



Tektronix documents require the latest version of PDF Adobe Acrobat Reader.