Characteristics
SDH Generator Output
Electrical Output -
Data Rates:
STM-0: 51.84 MBps
STM-1: 155.52 MBps
Data Formats:
STM-0E: B3ZS
STM-1E: CMI
Signal Level at Transmit Output:
STM-0E:
±1.0 Vpk ±10% into 75 Ohm
STM-0E: (-6 dB)
STM-0E output: attenuated with 6 dB cable loss (-12.7 dB square-root
f characteristic cable)
STM-1E: ±0.5 Vpk ±10% into
75 Ohm
STM-1E(-6 dB): STM-0E output attenuated with 6 dB cable
loss (-12.7 dB square-root f characteristic cable)
Pulse Shape
at Transmit Output:
Meets ITU-T G.703 Pulse Masks.
Return
Loss: >15 dB
Connectors:
Unbalanced BNC, 75 Ohm to ground.
Opt. 11: 1.6/5.6, 75 Ohm to ground.
Optical Output
-
Data Rates:
STM-0: 51.84 MBps
STM-1: 155.52 MBps
STM-4: 622.08 MBps
Optical Module Options:
Opt.
01: Electrical only, STM-0/1E
Opt. 03: 1310 nm, IR, STM-0/1
Opt. 04: 1310 nm, IR, STM-0/1/4
Opt. 05: 1550 nm, LR,
STM-0/1/4
Opt. 06: 1310/1550 nm, STM-0/1/4
Signal Level
and Wavelength:
1310 nm: -10 dBm, typical (Opt. 03, 04, 06)
1550 nm: 0 dBm, typical, (Opt. 05, 06)
Pulse Shape:
Meets ITU-T G.957 Eye Pattern Masks.
Wavelength:
1308 nm, typical (Opt. 03, 04, 06)
1550 nm, typical (Opt.
05, 06)
Spectral Width:
1310 nm: <4 nm (Opt. 03,
04, 06)
1550 nm: <1 nm (Opt. 05, 06)
Laser Classification:
EN60825-1 (Class 1), 21CFR1000 (Class I)
Connectors:
User-selectable when ordering –
Opt. 31: FC-PC
Opt. 32: ST
Opt. 33: SC
Opt. 34: DIN
Other connector
types - consult factory
SDH Signal Structure
Payload -
Payload Channel (AU):
Concatenated VC4-4c
signal in STM-4
One active AU-3 in STM-0
One active
AU-4 in STM-1
One active AU-4 in STM-4
(other 3 channels
unequipped)
Unequipped Payload -
C2 byte is
set to 00.
Bulk fill set to 00.
SDH Internal Pattern
Generator
Patterns -
Bulk Fill in a selected AU
channel.
(AU-3 or AU-4)
PRBS: 29-1, 215-1, 220-1, 223-1; All 1s, All 0s, 8-bit
programmable word.
PRBS patterns can be inverted.
RSOH Orderwire - E1
RSOH User Byte - F1
MSOH Orderwire
- E2
POH User Byte - F2
DCC Bytes - D1-D3
DCC
Bytes - D4-D12
PRBS: 215-1; 220-1; 223-1
PRBS patterns can be inverted.
Error Types and Insert Rates -
Single or Continuous.
RS BIP B1
STM-0: 1.0e-3 to 1.0e-10
STM-1:
1.0e-4 to 1.0e-10
STM-4: 1.0e-5 to 1.0e-10
MS BIP B2
STM-0: 1.0e-3 to 1.0e-10
STM-1/4: 1.0e-4 to 1.0e-10
Path BIP B3
STM-0: 1.0e-3 to 1.0e-10
STM-1/4: 1.0e-4
to 1.0e-10
HP-REI G1
STM-0: 1.0e-3 to 1.0e-10
STM-1/4: 1.0e-4 to 1.0e-10
Payload (Pattern Bit Error)
1.0e-3 to 1.0e-10
Defects -
LOS, LOF,
LSS (Pattern Loss).
RS-TIM, MS-AIS, MS-RDI, AU-LOP, AU-AIS,
HP-RDI, HP-TIM, HP-PLM, HP-UNEQ, LP-RDI, LP-RFI, LP-TIM, LP-UNEQ,
LP-PLM, TU-AIS.
SDH Transmitter Clock
Internal
Clock Accuracy - ±4.6 ppm, for instrument calibrated within 36 months
External Clock Reference -
Rates:
2.048 MBps
±50 ppm
2.048 MHz ±50 ppm
1.544 MBps ±50 ppm
Input:
Unbalanced, 75 Ohm, BNC connector
G.703 signal
format
Recovered Clock:
Loop timing
Clock is
recovered from received signal
Transmit Line Frequency-Offset
Rate -
±100 ppm of nominal line rate
Resolution: 0.1
ppm
SDH Receiver Input
Electrical Input -
Data Rates:
STM-0: 51.84 MBps ±100 ppm
STM-1: 155.52 MBps
±100 ppm
Data Formats:
STM-0E: B3ZS
STM-1E: CMI
Signal Sensitivity/Equalization:
STM-0E: 0.5 Vpk min to 1.2 Vpk max
STM-0E -6 dB*1:
0.25 Vpk min to 0.6 Vpk max
STM-0E -12dB*2: 0.125 Vpk min to 0.35 Vpk max
STM-0E Monitor: 20 dB of flat loss below -6 dB
STM-1E: 0.35 Vpk min to 0.6 Vpk max
STM-1E -6 dB*3: 0.35 Vpk min to 0.6 Vpk max
STM-1E
-12 dB*4: 0.07 Vpk min to 0.3 Vpk max
STM-1E Monitor: 26 dB of flat loss below STM-1E level
*1 -6 dB cable loss at 25 MHz (-12.7 dB square-root
f characteristic cable)
*2 -12 dB cable loss at
25 MHz (-12.7 dB square-root f characteristic cable)
*3 -6 dB cable loss at 78 MHz (-12.7 dB square-root f characteristic
cable)
*4 -12 dB cable loss at 78 MHz (-12.7 dB
square-root f characteristic cable)
Signal Level Display:
Readout for: Electrical signal level in mV
Return Loss:
>15 dB
Connectors:
Unbalanced BNC, 75 Ohm to ground
Opt. 12 - 1.6/5.6, 75 Ohm to ground
Optical Input
-
Data Rates:
STM-0: 51.84 MBps (±100 ppm)
STM-1:
155.52 MBps (±100 ppm)
STM-4: 622.08 MBps (±100 ppm)
Maximum Input Power:
-7 dBm: Opt. 05 and 06 include a 10 dB
attenuator for use at 1550 nm
Operating Wavelength:
1310 nm and 1550 nm: 1100 nm to 1570 nm operating range
Signal
Sensitivity: -28 dBm for BER <10-10
Optical
Power Meter Accuracy:
±2 dBm, typical: For input power in a
range of -30 dBm to -6 dBm. Resolution 0.1 dBm.
Connectors:
User-selectable when ordering –
Opt. 31: FC-PC
Opt. 32: ST
Opt. 33: SC
Opt. 34: DIN
Other connector
types - consult factory
Through Mode:
Monitors a selected
channel while passing the signal through unchanged, both electrical
and optical.
Section Overhead
Access -
Set overhead bytes to any value from binary 00000000 to 11111111:
A1, A2, J0, E1, F1, D1 to D3, D4 to D12, K1, K2, S1, M1, E2.
View all Section Overhead bytes.
Clear text decode of S1 message
byte provided per G.707.
Add/Drop -
Orderwire
Access to E1 or E2 byte from RJ11 jack.
Insert data from the
Overhead Add/Drop connector into the Section DCC, Line DCC, E1, E2,
or F1 user byte.
Drops data from the Section DCC, Line DCC,
E1, E2, or F1 user byte out to the Overhead Add/Drop connector.
PRBS evaluation is provided internally for bytes E1, E2, F1,
F2, D1 to D3, D4, to D12.
K1 and K2 (APS) -
Set the APS Bytes, K1 and K2, to any code defined in ITU-G.783 Annex
A and G.841.
Selectable by clear text for all Span and Ring
messages.
Path Overhead
Access -
Set Path Overhead bytes to any value from binary 00000000 to 11111111:
C2, G1 (bits 5 to 7 only), F2, H4 (bits 1 to 6 only), F3, K3, N1.
View all Path Overhead bytes.
Clear text decode of C2
signal label per ITU-G.707.
Path Label Mismatch (PLM) and Unequipped
(UNEQ) detection.
Add/Drop -
Insert data from
the Overhead Add/Drop connector into the F2 user byte.
PRBS
can be used through F2 internally.
Trace Bytes J1,
J0 -
J1 HP-Trace: VC4 Overhead - User-defined 15-byte with
CRC, or 64-byte formats per ITU-T G.707.
J0 RS-Trace: User-defined
15-byte with CRC per ITU-T G.707.
Pointer Movement
Single - Single pointer justification.
Burst
- Bursts of two to eight pointer justifications spaced four frames
apart. All adjustments within a given burst are in the same direction.
Subsequent bursts are in alternating directions.
Continuous
- Pointer justifications occur continuously at a predetermined
rate in an incrementing, decrementing, or alternating direction. Rate
between movements: 2 ms to 10 s, with a resolution of 1 ms.
Set to Value - Set to a new location with or without the
NDF being set. Range is 0 to 1023 (783 to 1023 are illegal locations).
Pointer Test Sequences
AU and TU Pointer sequences available:
G.783(a) Single Alternating
G.783(b) Regular + Double
G.783(c) Regular + Missing
G.783(d) Double Alternating
G.783(e) Single
G.783(f) Burst
G.783(g1) Periodic
87-3
G.783(g2) Periodic 87-3 With Add
G.783(g3) Periodic
87-3 With Cancel
G.783(h1) Periodic
G.783(h2) Periodic
with Add
G.783(h3) Periodic with Cancel
Phase Transient
Pointer Adjustment Burst.
Pointer Direction - Positive
or Negative.
Initialization Period -
On or Off.
30-second burst of 1 pointer per second in the same direction
as the selected test, per ITU-T G.783.
Cooldown Period
-
On or Off.
This will last at least 60 seconds, for
an integral number of complete sequences, per ITU-T G.783.
Combined Jitter -
Simultaneous PDH mapping frequency
offset with ITU-T G.783 Pointer Sequences generation.
To enable
the measurement of combined mapping and Pointer Jitter.
SDH Measurements
SDH Anomalies - Error Count, Error
Rate, and Errored Seconds for: B1, B2, B3, TU Path BIP, Payload, MS-REI,
HP-REI, LP-REI.
Network Defects (Seconds) - LOS, LSS
(Pattern Loss), CTS Loss of AC Power.
SDH Defects (Seconds)
- RS-TIM, MS-AIS, MS-RDI, AU-AIS, AU-LOP, HP-RDI, HP-TIM, HP-UNEQ,
HP-PLM, LP-RDI, LP-RFI, LP-TIM, LP-UNEQ, LP-PLM, TU-AIS.
AU Pointer Measurements - NDF Sec., Illegal Sec., +Ve Just. Count,
-Ve Just. Count, Illegal Count, NDF Count, Pointer Value.
G.826 Error Analysis -
RS B1, MS B2, Path B3, AU-LOP, AU-AIS,
HP-REI, HP-TIM, HP-PLM, HP-UNEQ, LP-REI, LP-TIM, LP-UNEQ, TU-LOP,
TU-AIS Seconds and ratio.
Errored Blocks, ES, %ES, SES, %SES,
UAS, %UAS, CSES Periods, Background Block Errors, %Background Block
Error, Path UAS, %Path UAS.
G.826 Performance Analysis
-
Performance analysis performed as per user settable allocation
percentage for SDH and PDH.
Regeneration Section, Multiplex
Section, high- and low-order path layers are individually evaluated.
Analysis Results: Pass or Fail.
G.821 Analysis
-
Pattern Bit Seconds and % of total time.
Error-Count,
ES, DM, SES, UAS, EFS.
M.2101.1 Error Analysis -
B1, B2, B3, RS-TIM, MS-REI, MS-RDI, MS-AIS, AU-AIS, AU-LOP, HP-REI,
HP-TIM, HP-UNEQ, HP-PLM, HP-RDI, LP-REI, LP-TIM, LP-UNEQ, LP-PLM,
LP-RDI, LOS, OOF, TU-LOM, TU-AIS, TU-LOP, TU-BIP.
Errored Blocks,
ES, %ES, SES, %SES, CSES, UAS, %UAS, Background Block Errors, %Background
Block Error, Path UAS, %Path UAS.
M.2101.1 Performance
Analysis -
Test Types:
BIS (Bring Into Service).
PAR (Performance After Repair).
MAINT (Maintenance).
Custom (User Controls Performance Limits).
Automated Test
types allow Performance Analysis for Regeneration Section, Multiplex
Section, high- and low-order path layers based upon user-settable
allocation percentage.
Custom test type allows the user to
select the performance objective limits.
Analysis Results:
Acceptable, Provisional/Degraded, or Unacceptable.
SDH Standards Compliance
SDH Framing - G. 707
SDH Multiplexing - G.707
SDH Optical Interfaces
- G.957
SDH Electrical Interfaces - G.703
SDH Jitter Tolerance - G.825, G.958, O.172
SDH
Pointer Sequences - G.783
SDH Error Analysis - G.826, G.821
SDH Performance Analysis - M.2101.1
SDH Test Patterns - O.181, O.150, O.151
SDH
Availability Performance - G.827
CTS850 PDH/DS3 (45 MBps)
Tributary Specifications
(Opt. 38 provides PDH Tributaries,
Opt. 55 Provides 4DS3 - 45 MBps Mapping/Demapping function.)
2 MBps, 8 MBps, 34 MBps, 140 MBps, and 45 MBps Generator
The data format can be built upon the pattern generator framed or
unframed output at the PDH line/mapping rate or upon multiple layers
of user-configurable sub-multiplexing. A specific hierarchy of tributaries
can be selected and filled with a background pattern.
Electrical
Output -
Data Rates:
2 MBps (2.048 MBps)
8 MBps
(8.448 MBps)
34 MBps (34.368 MBps)
45 MBps (44.736 MBps)
140 MBps (139.264 MBps)
Formats:
2 MBps, 8 MBps,
34 MBps: HDB3, AMI
45 MBps: HDB3, B3ZS
140 MBps: CMI
Signal Level:
2 MBps: 3 Vpk ±0.3 V into 120
Ohm balanced
2 MBps: 2.37 Vpk ±0.237 V into 75 Ohm
8 MBps: 2.37 Vpk ±0.237 V into 75 Ohm
34 MBps:
1 Vpk ±0.1 V into 75 Ohm
45 MBps:
DS3 High:
0.9 ±0.2 V peak into 75 Ohm
DSX3: 0.36 V to 0.85 V peak into
75 Ohm
140 MBps: 1 Vpk-pk ±0.1 V into 75 Ohm
Pulse Shape:
Meets ITU-T G.703 Pulse Masks
Connectors:
2 MBps: 3-Pin Siemens 120 Ohm
2 MBps, 8 MBps, 34 MBps,
45 MBps, 140 MBps: BNC 75 Ohm
PDH Output -
2 MBps:
Internal Pattern Generator
Configured from
N × 64 Kbps
Drop from SDH TU12
Drop from demuxed 8 MBps
and above
From 2 MBps input (through mode)
8 MBps:
Internal Pattern Generator
Muxed up from 2 MBps
From 8 MBps input (through mode)
34 MBps:
Internal
Pattern Generator
Muxed up from 8 MBps
Drop from SDH
TU3
Drop from demuxed 140 MBps
From 34 MBps input (through
mode)
45 MBps:
Internal Pattern Generator
Drop
from SDH TU3
From 45 MBps input (through mode)
140 MBps:
Internal Pattern Generator
Muxed up from 34 MBps
Drop from SDH VC4
From 140 MBps input (through mode)
2 MBps, 8 MBps, 34 MBps, 45 MBps, and 140 MBps Internal Pattern
Generator
Framing -
2 MBps:
Unframed
N × 64 Kbps (with starting TS and range)
FAS (31 channel)
FAS + CRC4 (31 channel)
FAS + MFAS (30 channel)
FAS + CRC4 + MFAS (30 channel)
(G.704, G.737, G.732)
8 MBps:
Unframed
FAS (G.742)
34 MBps:
Unframed
FAS (G.751)
45 MBps:
Unframed
M13 (bulk filled)
C-Bit Parity (bulk filled)
140 MBps:
Unframed
FAS (G.751)
(for PDH Testing Line/Mapped)
Active Channel Patterns in selected measurement channels
N × 64 Kbps:
PRBS 29-1 per O.153
PRBS 211-1 per O.152
PRBS 215-1 per O.151
PRBS 220-1 per O.153
PRBS 223-1 per
O.151
All the above may be inverted
All 1s
All
0s
TS Idle
1020 Hz audio tone
2, 8, 34, 45, and
140 MBps:
PRBS 29-1 per O.153
PRBS 211-1 per O.152
PRBS 215-1 per O.151
PRBS 220-1 per O.153
PRBS 223-1 per
O.151
All the above may be inverted
All 1s
All
0s
Alternating 1/0
1 in 8
8, 16, and 24 bit
User-Selectable Pattern
Fill Patterns in background nonmeasurement
channels
N × 64 Kbps 2 MBps:
TS Idle (55 H)
PRBS
215-1
All 1s
All 0s
Alternating 1/0
8, 34, and 140 MBps:
PRBS 215-1 per O.151
PRBS 220-1 per O.153
PRBS 223-1
per O.151
All of above may be inverted
All 1s
All 0s
Alternating 1/0
Errors - Single,
Continuous, Burst (all are mutually exclusive and effective on active
channels only)
Error Type -
CRC (2 MBps only):
Min. rate 1.0e-8, max rate 1.0e-4
Parity Bit Error (45 MBps
Only):
P-Bit (M13, C-Bit)
CP-Bit (C-Bit)
REI
(FEBE) (C-Bit)
Frame Burst (available on any ONE enabled multiplexed
level)
(2, 8, 34, 45, and 140 MBps):
N < M < 1000
M = frame count
N = consecutive FAS Error count
Pattern Bit -
|
Payload Pattern bit at active pattern's rate
|
Line Code
|
|
64 Kbps, min 1.0e-6, max 1.0e-2
|
not applicable
|
|
2 MBps, min. 3.0e-8, max. 1.0e-2
|
min. 3.0e-8, max. 1.0e-2
|
|
8 MBps, min. 1.0e-9, max. 1.0e-2
|
min. 1.0e-9, max. 1.0e-2
|
|
34 MBps, min. 1.0e-9, max. 1.0e-2
|
min. 1.0e-9, max. 1.0e-2
|
|
45 MBps, min. 1.0e-9, max. 1.0e-2
|
min. 1.0e-9, max.1.0e-2
|
|
Parity (DS3-P)
|
min. 1.0e-9, max. 2.0e-4
|
|
Parity (DS3-CP)
|
min. 1.0e-9, max. 2.0e-4
|
|
FEBE (DS3)
|
min. 1.0e-9, max. 2.0e-4
|
|
140 MBps, min. 1.0e-9, max. 1.0e-2
|
not applicable
|
Alarm Insertion -
2 MBps:
AIS
RDI - NFAS bit 3 = 1
8 MBps:
AIS
RDI - FAS
bit 11 = 1
34 MBps:
AIS
RDI - FAS bit 11 = 1
45 MBps:
AIS (set 1010...for information)
RDI (X-Bit
= 0)
IDLE (set 1100...for information)
140 MBps:
AIS
RDI - FAS bit 13 = 1
TU12/TU3/VC4 Mapping
Mapping Signal Source for TU12, TU3, and VC4
|
Internal Generator
|
Received Signal
|
|
2 MBps
|
2 MBps
|
|
34 MBps
|
2, 34 MBps
|
|
45 MBps
|
45 MBps
|
|
140 MBps
|
2, 34, 140 MBps
|
Mapping mode -
Floating Asynchronous
TU12 Active Map Channel Selection -
Allows selection
of any one of 63 TU channels or all TU-12s simultaneously
Remaining
62 TU channels are background
TU3 Active Map Channel
Selection -
Allows selection of any one of 3 TU channels or
all TU-3s simultaneously
Remaining 2 TU channels are background
140 MBps Active Map Channel Selection -
Into
selected STM-1 VC4
TU Background Channels -
TU12 Background Channel Content:
When internal 2 MBps or 34 MBps
generator is used:
PRBS: 215-1 or Idle pattern (11010101)
When external source is used:
PRBS: 215-1
TU Background Channel Framing:
Always unframed unless
All TUs
TU3 Background Channel Content:
When internal
34 MBps generator is used:
VC3 is a bulk-filled pattern, Valid
Pointer, and BIP
Bulk fill data is 01, 02, and 03 for TU3 #1,
#2, and #3
TU Error Types (Single or Continuous) -
TU12 BIP-2
TU3 BIP-8
LP-REI
TU
Defects -
TU AIS
LP-RDI
TU Loss of Pointer
LP-UNEQ
TU Loss of Multiframe
LP-PLM
LP-RFI
LP-TIM
Transmitter Clock
Transmit Line
Frequency Offset -
Frequency offset rate:
2 MBps: ±100
ppm - nominal line rate
8 MBps: ±100 ppm - nominal line rate
34 MBps: ±100 ppm - nominal line rate
45 MBps: ±100 ppm
- nominal line rate
140 MBps: ±100 ppm of nominal line rate
Resolution: 0.1 ppm
2 MBps, 8 MBps, 34 MBps, 45 MBps,
and 140 MBps Receiver
Electrical Input -
Data
Rates:
2 MBps (2.048 MBps), ±150 ppm
8 MBps (8.448 MBps),
±150 ppm
34 MBps (34.368 MBps), ±150 ppm
45 MBps (44.736 MBps),
±150 ppm
140 MBps (139.264 MBps), ±150 ppm
Formats -
2 MBps: HDB3, AMI
8 MBps: HDB3, AMI
34 MBps: HDB3, AMI
45 MBps: HDB3, B3ZS
140 MBps: CMI
Impedance -
2 MBps: 120 Ohm balanced
2 MBps Bridged: 1 kilohm balanced
2 MBps, 8 MBps, 34 MBps,
45 MBps, 140 MBps: 75 Ohm unbalanced
PDH Receive Signal
Level -
ITU-T G.703 nominal pulse and signal level
Normal: Auto equalization of square-root f cable loss to ITU-T G.703
limits*1
2 MBps Bridged: Auto equalization of square-root
f cable loss to ITU-T G.703 limits*2
Protected
Monitor Point -20 dB: -15 to -23 dB flat loss
Protected Monitor
Point -30 dB: -23 to -31 dB flat loss
*1 2 MBps
and 8 MBps square-root f cable loss = 6 dB max
*1 34 MBps and 140 MBps square-root f cable loss = 12 dB max
*2 2 MBps Bridged only specified for 120 Ohm-balanced
cable
Connectors -
2 MBps: 3-Pin Siemens 120 Ohm
2 MBps, 8 MBps, 34 MBps, 45 MBps, and 140 MBps: BNC 75 Ohm
2 MBps, 8 MBps, 34 MBps, 45 MBps, 140 MBps Internal Pattern
Receiver
Pattern Receiver Source -
N/M × 64 Kbps
and 2 MBps:
2 MBps External
SDH TU12 Drop
Demuxed
8 MBps and above
8 MBps:
8 MBps External
Demuxed
34 MBps
34 MBps:
34 MBps External
SDH TU3 Drop
Demuxed 140 MBps
45 MBps:
45 MBps External
SDH TU3 Drop
140 MBps:
140 MBps External
SDH
VC4 Drop
Framing -
N/M × 64 Kbps and 2 MBps:
Unframed
FAS (31 channel)
FAS + CRC4 (31 channel)
FAS + MFAS (30 channel)
FAS + CRC4 + MFAS (30 channel)
(G.704, G.737, G.732)
8 MBps:
Unframed
FAS
(G.742)
34 MBps:
Unframed
FAS (G.751)
45 MBps:
Unframed
M13 (bulk filled)
C-Bit parity
(bulk filled)
140 MBps:
Unframed
FAS (G.751)
CAS (Signaling in TS 16) -
Bits displayed: a,
b, c, d
VFchan.: 1 to 30
Value displayed: 1 or 0
TU12/TU3/VC4 Demapping
Demapping TU12, TU3,
and VC4 Signal Drop to:
|
Internal Receiver
|
External Signal Output
|
|
2 MBps
|
2 MBps
|
|
34 MBps
|
34 MBps
|
|
45 MBps
|
45 MBps
|
|
140 MBps
|
140 MBps
|
Demapping mode -
Floating Asynchronous
TU12 Active Demap:
Channel Selection - Allows selection
of any one of 63 TU channels
TU3 Active Demap (either 34 MBit/s
or 45 MBit/s):
Channel Selection - Allows selection of any
one of 3 TU channels
140 MBps Active Demap Channel from selected
STM-1 VC4
TU Path Overhead
TU12 Path Overhead
Access -
Set Path Overhead bytes to any value from binary
00000000 to 11111111:
N2 and K4
V5 control (----xxx-)
(bits 5-7 only)
View all TU Path Overhead bytes
TU3
Path Overhead Access
Set Path Overhead bytes to any value from
binary 00000000 to 11111111: (set G1 bits 5 to 7 only)
C2,
F3, K3, N1 (H4 bits 1 to 6 only)
View all TU Path Overhead
bytes
Path Label Mismatch (C2) and Unequipped Detection
TU3 Path Trace Byte J1 -
Send user-defined 15-bytes
and CRC sequence or set to all "space" characters
View Path
Trace J1
TU12 Path Trace Byte J2 -
Send user-defined
15-byte and CRC sequence or set to 00000000 (Null)
View Path
Trace J2
TU Pointer Measurement
TU Pointer Interaction.
TU12, TU3, or AU4, but not at same time.
Single - Single pointer justification (increment or decrement).
Burst - Bursts of two to eight pointer justifications spaced
four multiframes apart. All adjustments within a given burst are in
the same direction. Subsequent bursts are in alternating directions.
Continuous - Pointer justifications occur continuously
at a predetermined rate in an incrementing, decrementing, or alternating
direction. Rate between movements: 48 ms to 10 s, with a resolution
of 1 ms.
Set to Value -
Set to a new location with
or without the NDF being set.
TU12 Range is from 0 to 1023
(140 to 1023 are illegal locations).
TU3 Range is from 0 to
1023 (783 to 1023 are illegal locations).
TU Pointer sequences
available:
G.783(a) Single Alternating
G.783(b) Regular
+ Double
G.783(c) Regular + Missing
G.783(d) Double
Alternating
G.783(e) Single
G.783(f) Burst
G.783(g1)
Periodic 87-3
G.783(g2) Periodic 87-3 With Add
G.783(g3)
Periodic 87-3 With Cancel
G.783(h1) Periodic
G.783(h2)
Periodic with Add
G.783(h3) Periodic with Cancel
Phase
Transient Pointer Adjustment Burst:
TU-3 Periodic 85-5
TU-3 Periodic 85-5 With Add
TU-3 Periodic 85-5 With Cancel
TU-12 Periodic 35-1
TU-12 Periodic 35-1 With Add
TU-12 Periodic 35-1 With Cancel
Pointer Direction
- Positive or Negative.
Initialization Period -
On or Off.
30-second burst of 1 pointer per second in
the same direction as the selected test, per ITU-T G.783.
Cooldown Period
On or Off.
This will last at
least 60 seconds, for an integral number of complete sequences, per
ITU-T G.783.
PDH and TU Measurements
PDH Error
Count, Error Rate, and Error Seconds for -
FAS
CRC-4
(2 MBps only)
Pattern Bit
Code violation
DS3
Frame Bit Error, DS3 Parity (P-Bit), DS3 Parity (CP-Bit), DS3 REI(FEBE)
TU Error Count, Error Rate, and Error Seconds for -
TU12 BIP-2
TU3 BIP-8
LP-REI
PDH
Defect Seconds for -
AIS
RDI
Loss of Sync Sequence
(LSS)
Loss of Frame (FAS)
Loss of Signal
Loss
of Power
DS3 AIS, DS3 RDI, DS3 IDLE
TU Defect
Seconds for -
TU AIS
LP-RDI
LP-TIM
LP-RFI
LP-UNEQ
LP-PLM
TU-LOP
TU-LOM
TU Pointer Measurements
|
Seconds:
|
Count:
|
|
LOP
|
Illegal pointers
|
|
Illegal pointers
|
Positive justifications
|
|
NDF
|
Negative justifications
|
G.826 Analysis for TUs -
TU12 BIP-2,
TU3 BIP-8, REI
Seconds and ratio
Errored Blocks, ES,
%ES, SES, %SES, UAS, %UAS, CSES Periods, Background Block Errors,
%Background Block Errors, Path UAS, %Path UAS, Verdict Analysis
TU3 BIP-8 and HP-REI -
Seconds and ratio
Errored Blocks, ES, %ES, SES, %SES, UAS, %UAS, CSES Periods,
Background Block Errors, %Background Block Error, Path UAS, %Path
UAS, Verdict Analysis
G.821 Analysis for PDH -
PDH Frame and CRC-4 Errors, Seconds and Ratio
Errored
Blocks, ES, %ES, SES, %SES, UAS, %UAS, CSES period, BBE, %BBE, Path
UAS, %Path UAS, Verdict Analysis
Payload (Pattern
Bit Errors) -
Seconds and % of total time
Error-Count,
ES, SES, UAS, EFS, DM
M.2100 Analysis for PDH -
In-Service Seconds and % of total time: ES, SES, UAS, EFS, Path
UAS
Out-of-Service Seconds and % of total time: ES, SES, UAS,
EFS, Path UAS
G.826 Analysis of PDH -
(Near
End and Far End)
In service for selected rate*1:
ES, %ES, SES, %SES, UAS, %UAS, CSES, Errored Blocks, Background
Block Errors, %Background Block Error, Path UAS, %Path UAS
For remote-selected rate*1:
ES, %ES, SES, %SES,
UAS, %UAS, PUAS, %PUAS
*1 (within channel(s)
under test at all enabled MUX levels)
Verdict Analysis
PDH Standards Compliance
PDH Mapping/Demapping - G.707
PDH Line Interfaces - G.703
PDH Jitter
Tolerance - G.823, G.824, O.172
PDH Error Analysis
- G.821, G.826, M.2100
PDH Availability Performance
- G.827
PRBS Test Patterns - O.151, O.152, O.153
Monitor Mode Levels - G.772
PDH Framing - G.704, G.737, G.732, G.742, G.751
CTS850 Opt. 14 Jitter and
Wander Specifications
Jitter/Wander Generation
Meets or exceeds the requirements of ITU-T G.823, G.825, O.171.
Exceeds requirements of ITU-T O.172.
Jittered Line Output
- Sinusoidal modulation of transmit clock frequency, applicable
to any SDH or PDH data rate, except 8 MBps (E2).
Jitter
Frequency Range - 12 µHz up to 5.00 MHz.
Modulation
Range - Modulation is selectable up to the following limits, which
depend on the rate:
Jitter Amplitude Range - Up to
300 UI.
Wander Amplitude Range - Up to 100,000 UI.
|
Rate
|
A0
|
A2
|
A3
|
A4
|
f8
|
f1
|
f2
|
f3
|
f4
|
f5
|
|
E1
|
100,000 UI
|
10.0 UI
|
3.00 UI
|
1.00 UI
|
12 µHz
|
30 mHz
|
300 Hz
|
9.00 kHz
|
33.3 kHz
|
100 kHz
|
|
E3
|
100,000 UI
|
10.0 UI
|
3.00 UI
|
1.00 UI
|
12 µHz
|
30 mHz
|
300 Hz
|
10.0 kHz
|
267 kHz
|
800 kHz
|
|
E4
|
100,000 UI
|
10.0 UI
|
3.00 UI
|
1.00 UI
|
12 µHz
|
30 mHz
|
300 Hz
|
20.0 kHz
|
1.17 MHz
|
3.50 MHz
|
|
DS3 (45 MBps)
|
100,000 UI
|
10.0 UI
|
3.00 UI
|
1.00 UI
|
12 µHz
|
30 mHz
|
300 Hz
|
16.7 kHz
|
133 kHz
|
400 kHz
|
|
STM-0*1
|
100,000 UI
|
10.0 UI
|
3.00 UI
|
1.00 UI
|
12 µHz
|
30 mHz
|
300 Hz
|
10.0 kHz
|
133 kHz
|
400 kHz
|
|
STM-0*1
|
100,000 UI
|
10.0 UI
|
3.00 UI
|
1.00 UI
|
12 µHz
|
30 mHz
|
300 Hz
|
35.0 kHz
|
433 kHz
|
1.30 MHz
|
|
STM-4*1
|
100,000 UI
|
10.0 UI
|
3.00 UI
|
1.00 UI
|
12 µHz
|
30 mHz
|
300 Hz
|
125 kHz
|
1.67 MHz
|
5.00 MHz
|
*1 When equipped with bulk fill payload.
Amplitude Accuracy -
±5% ±0.06 UI, at 622 MBps Line
Output.
±5% ±0.04 UI, at 622 MBps Clock Output and 45 MBps
Line Output.
±5% ±0.03 UI, for all other rates, Line or Clock
Output.
Amplitude Resolution - 0.01 UI.
Frequency Accuracy - ±1%, below 1.00 kHz; ±5 ppm, above 1.00 kHz.
Frequency Resolution - Three decimal places.
Jittered Clock Output - Operates in addition to the jittered
line output.
Output Level, typical -
0.8 Vpk-pk output (for all rates) is AC-coupled and terminated with
unbalanced 75 Ohm.
2 MHz G.703 output is compliant with G.703
2048 kHz synchronization interface specifications.
Nominal Clock Rates - 2 MHz, 34 MHz, 140 MHz, 52 MHz, 155 MHz,
622 MHz, or 45 MHz. Can be set independently of transmit-line rate.
Connector - Rear-panel, unbalanced 75 Ohm BNC.
Jitter and Wander Analysis for SDH/PDH
Jitter Measurement
Peak-to-peak or RMS jitter measurement of the Clock or Line
input. Meets or exceeds the requirements of ITU-T G.783, G.823, G.824,
G.825, G.958, O.171. Exceeds requirements of new ITU-T O.172.
Jitter Measurements - Peak-to-peak Jitter (UI), Positive
Peak Jitter (UI), Negative Peak Jitter (UI), Jitter Hit Seconds, Jitter
Unlocked Seconds, RMS (UI).
Jitter Measurement Accuracy
(Line Wideband) -
5% A ±0.035 UI (except 622 MBps).
5% A ±0.07 UI (622 MBps only).
Frequency Response
- For f, HPI > 0 dB/decade, down to 0.1 Hz.
Timing
Quality (Video Related Measurements) -
Pointer Event Seconds,
Current Frequency Drift Rate (ppm/s), Maximum Frequency Drift Rate
(ppm/s).
Current Frequency, Maximum Frequency, Minimum Frequency.
Normal and Extended Jitter Measurement Resolution and
Range -
Normal Resolution: 0.005 UI. Resolution is 0.1 UI
for Fullband (0.1 Hz Highpass). Resolution for RMS is 0.001 UIRMS.
Extended Resolution: 0.01 UI, except fullband 0.1 Hz,
0.1 UI.
Input Phase Tolerance - Input phase tolerance
exceeds 300 UIpk-pk, to accommodate worst-case tributary
pointer jitter, exceeding requirements of new O.172.
ITU-T
Conformance Tests -
Built-in conformance tests automatically
execute jitter/wander tests according to the relevant standards for
equipment and network interfaces.
Output Jitter: ITU-T G.823,
G.824, G.825.
Input Jitter Tolerance: ITU-T G.823 (Standard
and National), G.824, G.825, G.958 (Type A/ B).
Jitter Transfer
Function: ITU-T G.735, G.751, G.752, G.958 (Type A/B).
Pointer
Jitter : ITU-T G.783.
Range - See graph.
Where values are specified by rate in the table below:
|
Frequency Scale in Hz Rate
|
A4
|
f1
|
f2
|
f3
|
f4
|
f5
|
f6
|
f7
|
|
2 MBps
|
0.5 UI
|
0.1 Hz
|
10.0 Hz
|
300 Hz
|
1.9 kHz
|
3.2 kHz
|
38.4 kHz
|
100 kHz
|
|
34 MBps
|
0.5 UI
|
0.1 Hz
|
10.0 Hz
|
300 Hz
|
8.0 kHz
|
13.3 kHz
|
160 kHz
|
800 kHz
|
|
45 MBps
|
0.5 UI
|
0.1 Hz
|
10.0 Hz
|
300 Hz
|
16 kHz
|
26.7 kHz
|
320 kHz
|
400 kHz
|
|
140 MBps
|
0.5 UI
|
0.1 Hz
|
10.0 Hz
|
300 Hz
|
16 kHz
|
26.7 kHz
|
320 kHz
|
3.5 MHz
|
|
52 MBps
|
0.5 UI
|
0.1 Hz
|
10.0 Hz
|
300 Hz
|
16 kHz
|
26.7 kHz
|
320 kHz
|
400 kHz
|
|
155 MBps
|
0.4 UI
|
0.1 Hz
|
10.0 Hz
|
300 Hz
|
16 kHz
|
26.7 kHz
|
320 kHz
|
1.3 MHz
|
|
622 MBps
|
0.3 UI
|
0.1 Hz
|
10.0 Hz
|
300 Hz
|
40 kHz
|
68 kHz
|
1.33 MHz
|
5.0 MHz
|
Fixed Error (Intrinsic) Noise with Clock, Typical
|
For peak-to-peak measurement, in UIpk-pk
|
|
Rate
|
Highband
|
Wideband
|
Fullband (10 Hz)
|
Fullband (1 Hz)
|
Fullband (0.1 Hz)
|
|
2 MBps
|
0.01
|
0.015
|
≤0.1
|
≤0.2
|
≤0.3
|
|
34 MBps
|
0.02
|
0.03
|
≤0.1
|
≤0.2
|
≤0.3
|
|
45 MBps
|
0.02
|
0.03
|
≤0.1
|
≤0.2
|
≤0.3
|
|
140 MBps
|
0.04
|
0.05
|
≤0.1
|
≤0.2
|
≤0.3
|
|
52 MBps
|
0.02
|
0.03
|
≤0.1
|
≤0.2
|
≤0.3
|
|
155 MBps
|
0.02
|
0.03
|
≤0.1
|
≤0.2
|
≤0.3
|
|
622 MBps
|
0.03
|
0.05
|
≤0.7
|
≤0.7
|
≤1.0
|
For extended range, fixed error shall be less than
or equal to 0.1 UI plus the value listed above.
For RMS measurements,
fixed error shall be less than or equal to 0.01 UIRMS at
all rates.
Fixed Error (Intrinsic) Noise with PRBS Data
Signal, Typical
|
For peak-to-peak measurement, in UIpk-pk
|
|
Rate
|
Highband
|
Wideband
|
Fullband (10 Hz)
|
Fullband (1 Hz)
|
Fullband (0.1 Hz)
|
|
2 MBps
|
0.025
|
0.035
|
≤0.1
|
≤0.2
|
≤0.3
|
|
34 MBps
|
0.025
|
0.035
|
≤0.1
|
≤0.2
|
≤0.3
|
|
45 MBps
|
0.025
|
0.035
|
≤0.1
|
≤0.2
|
≤0.3
|
|
140 MBps
|
0.025
|
0.035
|
≤0.1
|
≤0.2
|
≤0.3
|
|
52 MBps
|
0.025
|
0.035
|
≤0.1
|
≤0.2
|
≤0.3
|
|
155 MBps
|
0.025
|
0.035
|
≤0.1
|
≤0.2
|
≤0.3
|
|
622 MBps
|
0.05
|
0.07
|
≤0.75
|
≤0.7
|
≤1.0
|
For extended range, fixed error shall be less than
or equal to 0.1 UI plus the value listed above.
For RMS measurements,
fixed error shall be less than or equal to 0.01 UIRMS at
all rates.
Jitter Measurement Accuracy - Jitter measurement
accuracy is a function of the modulation frequency and the highpass
filter chosen. Measured jitter frequency response is expressed by
the equation below, where fLC is the lower cutoff frequency
and fUC is the high-frequency cutoff (defined in table
following). Passband is from fLC to fUC. Uncertainty
= ±5% A ±fixed error, where A is the actual jitter at the input.
Input Phase Tolerance - Input phase tolerance exceeds
300 UIpk-pk, to accommodate worst-case tributary pointer
jitter, exceeding requirements of new O.172.
Jitter Measurement
Function Frequency Response -
Measurement function meets the
requirements of new ITU-T O.172 (supports ITU-T G.783, G.823, G. 824,
G.825, G.958, etc.).
Lower cutoff (highpass) is first order
(-20 dB/decade). For E1, E3, and E4, this response is 20 dB/decade
down to less than 0.1 Hz in wideband mode. Upper cutoff (lowpass)
is third order (-60 dB/decade).
Cutoff frequencies are ±10%
except E1 (2 MBps) is +100%/-10%.
Frequency Cutoff
Values
|
Rate
|
Fullband fLC
|
Wideband fLC
|
HighBand fLC
|
RMS fLC
|
fUC
|
|
E1
|
0.1, 1, or 10 Hz
|
20.0 Hz
|
700 Hz or 18.0 kHz
|
12.0 kHz
|
100 kHz
|
|
E3
|
0.1, 1, or 10 Hz
|
100 Hz
|
10.0 kHz
|
12.0 kHz
|
800 kHz
|
|
E4
|
0.1, 1, or 10 Hz
|
200 Hz
|
10.0 kHz
|
12.0 kHz
|
3.50 MHz
|
|
DS3
|
0.1, 1, or 10 Hz
|
10.0 Hz
|
30.0 kHz
|
12.0 kHz
|
400 kHz
|
|
STM-0
|
0.1, 1, or 10 Hz
|
100 Hz
|
20.0 kHz
|
12.0 kHz
|
400 kHz
|
|
STM-1
|
0.1, 1, or 10 Hz
|
500 Hz
|
65.0 kHz
|
12.0 kHz
|
1.30 MHz
|
|
STM-4
|
0.1, 1, or 10 Hz
|
1000 Hz
|
250 kHz
|
12.0 kHz
|
5.00 MHz
|
Jitter Clock Input - Input to measure jitter
on a clock signal.
Nominal Clock Rates: Any supported SDH or PDH
rate, except 8 Mbps (E2). Rate is independent of the receive line
rate.
Frequency Tolerance: Nominal rate ±100 ppm.
Input
Amplitude: 0.4 Vpk-pk minimum, 1.5 Vpk-pk maximum
amplitude.
Connector: Rear-panel, unbalanced 75 Ohm BNC.
Jitter Output - Demodulated jitter from the receiver.
The output is filtered by any measurement filters selected.
Connector:
Rear-panel 50 Ohm BNC.
Sensitivity, typical:
Normal
measurement range: 100 mV/UI.
Extended measurement range: 2.65 mV/UI.
Output Level, typical: ±1 V, centered at 0 V ±100 mV.
Accuracy: ±10%, in addition to measurement inaccuracy.
Lock Time -
<10 seconds wideband or highband or fullband
(10 Hz) highpass filter.
<30 seconds fullband, 1.0 Hz highpass
filter.
<60 seconds fullband, 0.1 Hz highpass filter.
Wander Measurements
Supports ITU-T G.813,
G.812, ETS300 462-n and O.171. Exceeds requirements of O.172.
Peak-to-Peak Wander, TIE (Time-Interval Error)/MTIE, TDEV, Current
Frequency, Maximum Frequency, Minimum Frequency.
TIE Accuracy
- 0.5%
MTIE Algorithm - 0.5%
TDEV Accuracy
- 0.5%
TIE Range - ≥2.1 * 1017 ns
Jitter
Frequency Range - 12 µHz up to 5.00 MHz
Peak-to-Peak and
TIE Measurement
|
Fixed Error
|
Z0 is TIE, (tau) is observation period
|
|
Range:
|
2.1*1017 ns
|
|
Accuracy:
|
±0.5% ±Z0(tau) where:
|
|
Z0(tau)(nsec)
|
Observation Interval, tau(sec)
|
|
2.5 + 0.0275 tau
|
0.05 ≤ tau ≤ 1,000
|
|
29.0 + 0.0010 tau
|
tau > 1,000
|
Sample Rate: 50 Hz
Anti-alias filter: 10 Hz
±10% first order roll-off, according to O.172
Resolution: 0.3 ns
or better
MTIE Measurement
|
Z1 error due to MTIE
algorithm:
|
|
Z0 + Z1 = Z3
|
|
Range:
|
Limited only by disk space on the PC
|
|
Accuracy:
|
±1.0% ±Z3(tau) where:
|
|
Z1(tau)(nsec)
|
Observation Interval, tau(sec)
|
|
3.0 + 0.0330 tau
|
0.05 ≤ tau ≤ 1,000
|
|
35.0 + 0.0012 tau
|
tau > 1,000
|
Sample Rate: 50 Hz
Anti-alias filter: 10 Hz
±10% first order roll-off, according to O.172
Resolution: 0.3 ns
or better
TDEV Measurement
|
Z2 is TDEV algorithm error
|
|
Z0 + Z2 = Z4
|
|
Range:
|
0.02 s to 167,700 s
|
|
Accuracy:
|
±1.0% ±Z4(tau) where:
|
|
Z2(tau)(nsec)
|
Observation Interval, tau(sec)
|
|
3.0 + 0.0330 tau
|
0.05 ≤ tau ≤ 1,000
|
|
35.0 + 0.0012 tau
|
tau > 1,000
|
Sample Rate: 50 Hz
Anti-alias filter: 10 Hz
±10% first order roll-off, according to O.172
Resolution: 0.3 ns
or better
ITU-T Conformance tests -
Built-in conformance
tests automatically execute jitter/wander tests according to the relevant
standards for equipment and network interfaces.
Input Wander
Tolerance: ITU-T G.823 (Standard and National), G.824, G.825, G.958
(Type A/B).
Timing Quality (Video Related Measurements)
-
Current Frequency, Maximum Frequency, Minimum Frequency,
Frequency Drift Rate
|
Frequency Measurement
|
|
Resolution:
|
1 Hz absolute (0.01 ppm relative)
|
|
Accuracy:
|
±0.1 ppm (with respect to source clock)
|
|
Frequency Drift Rate
|
|
Range:
|
10,000 ppm/sec
|
|
Accuracy:
|
<1% ±0.01 ppm/sec
|
|
Bandwidth:
|
0 Hz to 0.5 Hz
|
|
Resolution:
|
0.001 ppm/sec
|
ITU-T JITTER/WANDER STANDARD CONFORMANCE TESTS
Built-in conformance tests automatically execute jitter/wander
tests according to the relevant standards for equipment and network
interfaces.
Conformance tests use the selected data or clock
input/output signals and then automatically choose the correct test
signal format, adjust parameters as needed, and display the test results
in graphical and/or text format.
Default test parameters are
provided and are selectable/adjustable by the user.
Test Results
Results may be stored to floppy disc or printed to printer and/or
floppy disc (BMP format).
Graphical results have interactive
cursors for value readout, plus tabular reporting of results.
Standard specification limits are displayed for pass/fail determination.
Output Jitter
|
Rate (MBit/s MHz)
|
ITU-T Conformance
|
|
52
|
SONET
|
|
155
|
G.825
|
|
622
|
G.825
|
|
2
|
G.823
|
|
34
|
G.823
|
|
45
|
G.824
|
|
140
|
G.823
|
Range: 0 to 300 UIpk-pk; refer to Jitter
Measurement specification.
Test: Measures wideband and highband
jitter over default measurement interval of 60 sec (selectable 1 sec
to 99 days).
Results: Output jitter (UIpk-pk) with
specification limits.
Input Jitter/Wander Tolerance
|
Rate (Mbps MHz)
|
ITU-T Conformance
|
|
52
|
SONET
|
|
155
|
G.825
|
|
|
G.958 Type A
|
|
622
|
G.958 Type B
|
|
2
|
G.823 Standard
|
|
|
G.823 National
|
|
34
|
G.823
|
|
45
|
G.824
|
|
140
|
G.823
|
Range: 0 to 2x tolerance mask specification; refer
to Jitter/Wander Generation specification.
Test: Measures tolerance
to jitter/wander at a number of frequencies (selectable 6 to 48) over
a range of frequency (selectable from 12 MHz to 5 MHz); onset of errors
or 1 dB power penalty technique.
Results: Input jitter/wander
tolerance graph with specification limit mask or tabular report.
Jitter Transfer Function
|
Rate (Mbps MHz)
|
ITU-T Conformance
|
|
52
|
SONET
|
|
155
|
G.958 Type A
|
|
|
G.958 Type B
|
|
622
|
G.958 Type A
|
|
|
G.958 Type B
|
|
2
|
G.735
|
|
34
|
G.751
|
|
45
|
G.752
|
|
140
|
N/A
|
Range: +3 to -50 dB, resolution 0.01 dB
Accuracy
(typical): ±0.05 dB
Noise floor (typical): <-60 dB rel.
1 UI
Test: Measures jitter transfer function at a number of
frequencies (selectable 6 to 48) over a range of frequency (selectable
from 12 MHz to 5 MHz); systematic errors are reduced by an automatic
calibration cycle and intrinsic noise is reduced using correlation
analysis (which provides superior performance than conventional narrowband
filter techniques)
Results: Jitter transfer function graph
with specification limit mask or tabular report
Pointer Jitter
ITU-T conformance: G.783
Range: 0 to 300 UIpk-pk; refer to Jitter Measurement specification
Pointer test sequence:
refer to Pointer Sequence Generation specification
Test: Measures
wideband and highband PDH jitter while pointer sequence executes;
includes initialization, cool-down phases, and an integral number
of test sequences, as defined in ITU-T G.783; automatically synchronizes
measurement interval with pointer anomalies
Results: Wideband
and highband pointer jitter (UIpk-pk) with specification
limits
Real-Time Wander Analyst Software for CTS850
Real-Time Wander Analyst software works in conjunction with the Tektronix
CTS850 or SJ300E test sets. The software provides full wander TIE,
MTIE, and TDEV analysis according to the most recent ITU-T, ETSI,
ANSI, and Bellcore standards. The Windows-compatible PC software uploads
TIE wander measurement data from the test set at a sampling rate of
50 Hz (in accordance with ITU-T and ETSI requirements), stores the
data at a rate of 50, 1 or 0.1 Hz (selectable) and simultaneously
calculates MTIE and TDEV using efficient algorithms.
In addition
to the ITU-T and European ETSI specifications, real-time Wander Analyst
also includes a full suite of North American SONET and ANSI specification
limits. The software provides a hi/lo envelope TIE plot to show transients,
full zoom control using cursors, and calculates frequency offset and
drift rate in accordance with ANSI-approved methodology. Results can
be easily transferred to other Windows applications for report documentation.
- TIE, MTIE, and TDEV wander analysis
- Calculation
and display of frequency offset and drift rate from TIE data
- SDH and SONET compatible
- Windows 95/98/NT compatible
- Comprehensive support for new, revised, and draft ITU-T, ETSI,
ANSI, and Bellcore wander specifications
- Automatic mask testing
for easy conformance test documentation
- Interactive use for
design verification and performance assessment
- Flexible TIE
data acquisition and storage control
- Efficient algorithms
for speedy calculation of MTIE and TDEV
SDH/SONET Compliance
Test
MTIE and/or TDEV SDH/SONET test specification masks according
to:
Primary Reference Clock -
PRC, ITU-T G.811,
and ETS 300 462-6
PRS, GR-2830 CORE
Wander generation,
Wander output, Phase transient
Slave Clocks -
SSU, ITU-T G.812 Type I, ETS 300 462-4
Clock, ITU-T G.812
Type II, Type III
Clock, ITU-T G.812 Type IV
Clock,
ITU-T G.812 Type V, Type VI
Clock, GR-1244-CORE
Wander
generation; Wander tolerance; Noise transfer; Transient response
SDH/SONET Equipment Clock -
SEC ITU-T G.813
Opt. 1, ETS 300 462-5
SEC ITU-T G.813 Opt. 2
SMC, GR-253-CORE
Wander generation; Wander tolerance; Noise transfer; Transient
response
SDH/PDH and Sync Network Interface -
SDH and PDH Sync Network, ETS 300 462-3
PRC; SSU; SEC
equipment and PDH distribution output
SDH and PDH Transport
Network, ETSI DEN/TM 3067
2, 34, and 140 MBps output wander
SONET and Sync Network Interface -
SONET Sync
Network, ANSI T1.101
SONET Network, ANSI T1.105.03
SONET
Network, ANSI T1.105.09
DS3 Metallic Interface, T1.404
HDSL Network -
HDSL Network, ETS 152
Output
wander
Real-Time Wander Analyst Software
Test Set Requirements - CTS850 Opt. 14 must be installed, System
Software Version 2.18 or higher
Recommended PC Requirements
-
Processor: Pentium - Class 90 MHz or faster
Operating
system: Windows 95/98/NT
Memory: 16 MB minimum
Hard
disk: 2.5 MB + Data Storage
TIE Data Acquisition and
Storage -
Using RS-232 or GPIB interfaces
50 Hz rate:
1.4 MB/hour
1 Hz rate: 28.8 Kb/hour
0.1 Hz rate: 2.88 Kb/hour
Measurement duration: 10 to 109 seconds
Software
Processing Functions -
MTIE and TDEV calculation: done during
TIE data acquisition or postacquisition
TIE display: sample
or hi/lo envelope
Frequency offset and drift rate: in accordance
with ANSI T1.101 over a fixed or sliding window with user-definable
bandwidth
Remove frequency offset (for measurement of RTIE
and MRTIE parameters)
Graph scaling: automatic or manual, with
zoom, cursors
Documentation: print, clipboard copy
LEDs
SDH Status Indicators -
LOS, LOF, OOF,
LOP, MS-AIS, MS-RDI, AU-AIS, HP-RDI, Signal Present, Pattern Lock,
LSS, Error, Pointer Adj
SDH Histograms -
Error
Count (General), B1, B2, B3, MS-REI, HP-REI, Pattern Bit, Pointer
Jitter
Defects: On/Off
LOS, OOF, LOF, AU-LOP, MS-AIS,
HP-RDI, AU-AIS
Pattern Loss, Loss of Power
Pointers:
AU Pointer Value, Pointer Justification
Measurement
Utilities -
Measurement Control
Manual Start/Stop
Timed: 1 s to 99 days with 1 s resolution
Continuous
Histogram Display Resolution
High: 1 sec (displays 2 hours
with 1 sec resolution)
Normal: 1 min, 5 min, 15 min, 1 hour
(displays 5 days with 1 min resolution)
Low: 15 min, 60 min,
4 hrs, 12 hrs (displays 75 days with 15 min resolution)
Result Logging -
All measurements are recorded with start,
stop time, and date
The current and previous results are stored
in memory both totalized and graphical
Both graphical and totalized
results can be stored on a disk
PDH and TU Status
Indicators -
TU-AIS
PDH AIS
LP-RDI
PDH
RAI
Histograms for PDH and TU -
Error Count
(General)
E1 Defects
TU-BIP, LP-REI
Pattern Bit,
Pointer Jitter
PDH and TU Defects -
On/Off
LOS, LOF, PDH-AIS, PDH-RAI, TU-LOP, TU-AIS, LP-RDI, TU-LOM, Pattern
Loss, Loss of Power
TU Pointers - TU Pointer Value,
Pointer Justification
Utilities
TroubleScan - Scans all measurement results for key violations
AutoScan
-
AutoScan to incoming signal (rate, mapping, framing, and
pattern)
Identifies incoming signal and presents graphical
display of AU and TU structure
Identifies TU signal status
and PDH mux structure by showing TU number, equipped versus unequipped,
alarms, and pattern
Stored Setups -
5 front-panel
setups in memory
200 front-panel setups per disk
Pass/Fail Tests -
Predefined Pass/Fail Tests can be created,
stored, and executed
Pass/Fail tests are stored on disk
200 Pass/Fail test setups per disk
Add/Drop Interface
for -
Data Communication Channels and User Channels.
A DB-37 female connector provides the interface to an external protocol
analyzer. Clock and data signals are differential TTL, conform to
V.11 specifications and are also compatible with single-ended TTL
signals.
Add/Drop: D1-D3, D4-D12, F1, F2, E1, E2
Connector:
37-Pin DIN (DTE and DCE)
RJ11-style handset jack for access
to E1/E2 bytes
Triggering -
Pulse at start
of each SDH frame, (Tx and Rx)
Connector: 37-Pin DIN
Error Output - B1, B2, B3 bit error selectable
Disk Drive -
3.5 inch, 1.44 MB, DOS compatible
Measurement Results
Stored Setups and Pass/Fail Tests
Printer -
Printer support: Epson, HP Thinkjet, ASCII
text
Serial Printer Port: V.24
Print to disk: BMP format,
Interleaf format, Encapsulated PostScript, ASCII text
Computer Interface -
IEEE-488.2 interface
RS-232-C
interface (DB9)
Help Mode - Online task-oriented
help
Display -
7-inch diagonal CRT, green phosphor
Resolution: 640 × 480 pixels
VGA output: 15-Pin connector
Environmental Specifications
Temperature -
Operating: 0 °C to +40 °C
Nonoperating: -40 °C to +70 °C
Altitude -
Operating: 4,572 m (15,000 ft.)
Nonoperating: 12,192 m (40,000 ft.)
Humidity
-
Operating:
To 95%, relative humidity at or below
+40 °C for 2 hours or less
To 90%, relative humidity at or
below 30 °C, continuous
Transportation Handling - Qualifies under National Safe Transit Association 1s Preshipment
Test; 1A-B-1
Physical Characteristics
|
Dimensions
|
mm
|
in.
|
|
Height:
|
165
|
6.5
|
|
|
191 with accessory pouch
|
7.5 with accessory pouch
|
|
Width:
|
362
|
14.25
|
|
Depth:
|
490 with front cover
|
19.25 with front cover
|
|
|
564 with handle extended
|
22.2 with handle extended
|
|
Weight
|
kg
|
lbs.
|
|
Net:
|
Approximately 8.7
|
Approximately 19.3
|
|
Shipping:
|
Approximately 14.1
|
Approximately 31
|
Power Requirements
|
Line Voltage
|
Line Frequency
|
|
100 V to 132 V
|
50/60 Hz
|
|
180 V to 250 V
|
40 Hz to 60 Hz
|
|
100 V to 132 V
|
400 Hz
|
|
Maximum current is 6 ARMS
|
Certifications and Compliances
EC Declaration
of Conformity - EMC.
Meets intent of Directive 89/336/EEC for
Electromagnetic Compatibility. Compliance was demonstrated to the
following specifications as listed in the Official Journal of the
European Communities:
EN 55011:
Class A Radiated
and Conducted Emissions.
Australia and New Zealand Declaration
of Conformance for EMC:
Meets Intent of Australian EMC Framework.
Compliance demonstrated to standard AS/NZS 2064.1/2.
EN 50082-1
Immunity:
IEC 801-2, Electrostatic Discharge Immunity.
IEC 801-3, RF Electromagnetic Field Immunity.
IEC 801-4, Electrical
Fast Transient/Burst Immunity.
IEC 801-5, Power Line Surge
Immunity.
FCC Compliance:
Emissions comply with FCC
Code of Federal Regulations 47, Part 15, Subpart B, Class A Limits.
European Union Compliance:
Low-Voltage Directive 73/23/EEC,
Amended by 93/68/EEC. EN 61010-1, Safety requirements for Electrical
equipment for measurement, control, and laboratory use.
Additional Compliance -
ANSI/ISA S82.02.01: Safety standard
for Electrical and Electronic Test, Measuring, Controlling, and Related
Equipment.
IEC1010-1: Safety Requirements for Electrical Equipment
for Measurement, Control, and Laboratory Use.
Approvals
-
U.S. Nationally Recognized Testing Laboratory Listing.
UL3111-1: Standard for Electrical and Electronic Measuring and
Test Equipment.
Canadian Certification -
CAN/CSA-22.2
No. 1010.1: Safety requirements for Electrical and Electronic Measuring
and testing Equipment.
Safety -
UL3111-1,
CSA1010.1, EN61010-1, IEC61010-1.
Operating temperature: +5
to +40 °C.
Max. Operating altitude: 2000 m.
Relative
Humidity (maximum operating) 80% for temperatures up to 31 °C, decreasing
linearly to 50% at 40 °C.
Equipment Type: Test and measuring.
Safety Class: Class I, as defined in IEC 1010-1, Annex H) - grounded
product.
Overvoltage Category: CAT II, (as defined in IEC1010-1,
Annex J).
Pollution Degree: Pollution Degree 2, (as defined
in IEC 1010-1). Note: rated for indoor use only.
Laser