Serial Data Link Analysis (SDLA)
|
Features & Benefits
- Analysis of High-speed Serial
Data Links provides insight into eye closure
- Feed Forward
(FFE), Decision Feedback (DFE), and Continuous Time Linear Equalization
(CTLE) of the signal opens the eye diagram enabling measurements from
the view of the receiver comparator (Option SLA)
- Simultaneously
view time-aligned waveforms from the perspective of near end, far
end, de-embedded, and equalized for insight of the complete link
- Improved user interface for fast switching of the Jitter Analysis
View in DPOJET, Waveform View, and Serial Data Link View
- Clock recovery software with unmatched flexibility for accurate and
repeatable measurement results
- S-parameter-based De-embedding
supports both fixture de-embed and channel de-embed for view of the
signal back towards the transmitter
- Parametric Channel Emulation:
View the performance of the link with a number of emulated channels
and only one transmitter signal acquisition
- "What-If" Analysis
using flexible insertion/removal of transmitter equalization parameters
Applications
- Characterize the performance
of advanced links using equalization
- Link budgeting and What-if
Analysis with emulation of a range of channels with a single measurement
- Evaluate Transmitter Equalization (De-emphasis/Pre-emphasis)
- Acquire precise waveform shape for simulations or other processing;
Rely on acquisition with state-of-the-art resolution, jitter, noise,
fixture de-embedding, and filtering
- Characterize the performance
for multi-gigabit standards such as SATA 6 Gb/s, USB 3.0, SAS, PCIe®, OIF CEI, XFP, IEEE 802.3 Ethernet Electrical Physical Layer,
SFP+, InfiniBand, and others
- Serial Data Link Design evaluation
with quick equalizer adjustments including up to 100 FFE and 40 DFE
taps. Equalizer taps can be calculated automatically or imported for
evaluation of proprietary designs
Version 1.1 with additional equalization, simpler user interface,
programmable interface support, and other improvements.
Modern Serial Data Link Designs
Acceleration of signaling
speeds creates a number of challenges for design and test. The designs
are evolving to address these challenges with equalization techniques
at the receiver; pre-emphasis or de-emphasis at the transmitter; with
dedicated fixtures for capturing the signal at a test point; and with
complex compliance-verification procedures.
Serial Data Link
Analysis (SDLA) has the Tools
The advanced techniques employed
by the designs call for advanced measurement solutions. The challenge
begins with the signal acquisition: capturing a signal through cables
and fixtures distort the signal shape; SDLA provides you with a fixture
de-embedding feature which allows you to remove the effects of the
fixture from the measurement. Fixture de-embedding and thus improved
accuracy of your measurement might make the difference between pass
and fail of your test. Another challenge results from the transmitter
signal shape. The signal no longer is a simple NRZ square-wave pattern.
Designers alleviate high-frequency loss in the media with transmitter
equalization features, that is, with pre-emphasis or de-emphasis of
the transmitter waveform. Correspondingly, transmitter signals today
need to be evaluated for this transmitter equalization; the SDLA software
allows for complete transmitter equalization insertion or removal.
Beyond Measurements at the Transmitter
An important
part of today’s evaluation of serial data links is the complicated
interaction between the measured waveform and the complex behavior
of the interconnect channel. It is no longer possible to assume that
if the transmitter output meets the eye diagram mask a design will
work against all channels up to a given loss. Instead, advanced link
test methods need to acquire the true transmitter waveform, then test
against several corner-case channels.
Virtual Channel versus
Physical Channel
In some cases this test can be performed
with real physical channels: connect the transmitter under test to
the suite of normative test channels, one channel at a time - and
for every channel evaluate the signal shape at the receiver end. Oscilloscope
measurement systems and DPOJET jitter and eye analysis software will
give you a complete measurement facility for accurate measurements
of the resulting waveform…but this methodology is still prone to other
errors: are your physical normative channels really normative? Certainly
each physical device has tolerances against the standard’s ideal values;
furthermore the physical channel set ages and deteriorates. A virtual
channel would be more stable.
Since physical corner-case channels
are typically not conveniently available, the transmitter test that
includes corner-case channels uses virtual channels based on the network
description file, in particular on S-parameter touchstone files. Such
description of compliance channels is part of new standards. Now the
measurement on your transmitter under test simply involves acquisition
of the transmitter signal. Then you connect the captured signal to
all desired test channels, one channel at a time – in software emulation,
rather than physically. This methodology is supported by SDLA; the
interaction of test channels with the transmitter can be viewed without
the need to reacquire the transmitter waveform. Unlike simple compliance
scripts often used for pass/fail decisions the Tektronix SDLA software
offers a rich set of views of the signal, supported by the most accurate
real-time oscilloscope acquisition system.
Equalize, then
Equalize Again
The equalization at the transmitter is one
tool in the arsenal of techniques fighting the loss and dispersion
in the interconnect: another one is the equalization at the receiver.
Receiver equalization in most modern NRZ systems falls under either
CTLE (Continuous Time Linear Equalization); FFE (Feed Forward Equalization,
also known as LFE – Linear Feedback Equalization); or DFE – Decision
Feedback Equalization. A receiver equipped with equalization is capable
of decoding signals which, when viewed as an eye diagram, produces
a closed eye. How can measurements be performed on a closed eye? The
equalization tools in the SDLA can open even a completely closed eye,
with your own equalizer tap values, or, at a push of a button, equalization
tap values will be found for you, for either equalizer, even on random
data. The speed of recalculation and the ease of use allow you to
easily modify system parameters, such as the number and weight of
taps, or the amount of pre- or de-emphasis; you can optimize the design,
develop what-if scenarios, or confirm your simulations over a range
of conditions.
Measurements and Jitter Analysis
Signals
processed with SDLA might require multi-UI measurements, jitter breakdown,
jitter bathtub analysis, or other evaluation. DPOJET (Option DJA)
is recommended for these tasks. SDLA and DPOJET work together to analyze
jitter, offer eye diagrams of equalized waveforms and a number of
other views and measurements.
Flexibility of Signal Path Topology
The SDLA package for Tektronix real-time oscilloscopes supports
a number of topologies for measurements besides the transmitter driving
an emulated (simulated) channel. Data can also be captured downstream
from the transmitter, for example at the receiver end of the serial
data channel, in which case channel de-embed, rather than emulation,
is used to view the signal at the transmitter end. Additionally, test
fixture effects can be removed or added as necessary.
The removal
of fixtures or channels decreases the signal-to-noise ratio and becomes
impossible if the loss is too high. Understanding the trade-offs and
limitations of signal processing is important.
Plot of Elements
of the System, Filtering
In many situations the information
about channels, represented by an S-parameter touchstone file or other
information about the system is not completely clear: a supplier might
have, for example, supplied you with a touchstone file without properly
labeling its ports. To resolve the port assignment and in general
to present a view of network response SDLA offers plots of the network’s
S21 parameters in both frequency domain and as an impulse response
in the time domain. Additionally, if the signal spectrum is not of
interest above some frequency, the signal-to-noise ratio of the resulting
traces will be improved by low-pass filtering the network response;
you will find simple-to-setup filters in the system blocks.
Network Measurement Tools
Whenever S-parameters of the network
are needed SDLA will accept data from either VNA or a TDR-base S-parameter
measurement system. We recommend Tektronix TDR hardware and Tektronix
IConnect® software for high-quality network measurements.
Amongst the advantages of using Tek TDR and IConnect is the preservation
of the DC values in the touchstone matrix, which is typically lost
with other measurement methods. SDLA accepts network description based
on other measurement methods, such as VNA data or field-solver calculation;
the DC measurement results might need to be extrapolated in the SDLA
in such cases.
Additional information
For additional
information we recommend the following resources: literature on the
DPO/DSA70000/B family of oscilloscopes, their probes and software
applications; literature on Tektronix TDR/TDT and the IConnect network
measurement software; and literature on SDLA package 80SJNB for sampling
oscilloscopes.
Characteristics
Transmitter Equalization
- 2-tap FFE, UI-spaced, or a custom FIR filter of 2000 taps max.
Configurable as either pre-emphasis or de-emphasis, insertion or removal.
Receiver Equalization, type -
CTLE: 2nd-order IIR
filter, or a custom FIR filter of 2000 taps max. FFE, up to 100 taps,
settable pre/post-cursor, whole UI or fractional spacing. DFE, up
to 40 taps. Taps can be set or trained.
Receiver Equalization,
training - Vertical eye-opening targeting algorithm. Random data
acceptable for training; repetitive pattern recommended for training
of highly distorted data. Pattern detection and export/import. Training
from unspecified tap values or adaptive from previously found or loaded
values.
Receiver Equalization availability - Option
SLA only.
Link Topology - Signal path consists of up
to: Transmitter equalizer, channel emulator, receiver equalizer, and
probing fixture de-embedding (attachable at one or the other end of
the channel). Bandwidth filter in all blocks except receiver equalizer.
Waveform at every node between blocks above available. See figure
above.
Channel emulation - 1-port, 2-port, or 4-port
Touchstone S-parameter matrix, with selectable port assignments, single-ended
or differential; or, a custom FIR filter of 2000 taps max. Used
parameter: S21 (insertion gain from transmitter to receiver).
Waveform record length - 30 MS typical, less if high
number of waveforms or measurement is active simultaneously. Equalized
waveform is limited to 2 MS.
Clock recovery - 1st-
or 2nd-order PLL. Variable loop bandwidth, damping ratio for 2nd-order
PLL and clock delay.
Programmatic Interface - GPIB.
Subset of commands available from the user interface.
Supported link topology
System Requirements
- DPO70000 and DSA70000 oscilloscope, either non-B or B version,
with bandwidth of 4 GHz or higher, with firmware version 4.2.0 or
greater. Firmware version 4.3.3 or greater is recommended for optimum
processing speed.
- 15 GB of disk space (more for file-backed
data objects created when performing up to 99 measurements on long
waveforms).
- If DPOJET is used with SDLA the DPOJET version
must be 1.2.1 or greater.
Ordering Information
The SDLA software for Tektronix
DPO/DSA70000/B oscilloscopes is offered in two versions:
- The SLE (Essentials) version supports all features except for the
Receiver Equalization block
- The SLA (Advanced) option, which
adds the Receiver Equalization block
To preinstall
on a new DPO70000, DSA70000, DPO70000B, or DSA70000B
|
Product
|
Option
|
Description
|
|
DPO/DSA70000/B
|
Opt. SLE
|
Add SDLA Essentials to DPO/DSA70000/B
|
|
DPO/DSA70000/B
|
Opt. SLA
|
Add SDLA Advanced to DPO/DSA70000/B
|
For users with existing DPO70000, DSA70000, DPO70000B,
or DSA70000B oscilloscopes
|
Product
|
Option
|
Description
|
|
DPO7UP
|
Opt. SLE
|
Add SDLA Essentials to DPO/DSA70000/B
|
|
DPO7UP
|
Opt. SLA
|
Add SDLA Advanced to DPO/DSA70000/B
|
|
DPO7UP
|
Opt. EQ
|
Upgrade from SDLA Essentials to SDLA Advanced
|
Note: The SDLA Software is supplied on the
internal hard drive of the oscilloscope, and can be downloaded for
free from www.tektronix.com. Software is enabled by a key code.
|
Product(s) are manufactured in ISO registered facilities.
|
|
Product(s) complies with IEEE Standard 488.1-1987, RS-232-C,
and with Tektronix Standard Codes and Formats.
|
55W-23293-0, 15-APR-2009
|
|
 |
(WebID: 15220)
|